db/SqlServer/jobs/jobAtualizaTabelasSistemaComercial.sql 0 → 100644
... ... @@ -0,0 +1,67 @@
  1 +USE [msdb]
  2 +GO
  3 +
  4 +/****** Object: Job [jobAtualizaTabelasSistemaComercial] Script Date: 02/24/2022 23:51:46 ******/
  5 +BEGIN TRANSACTION
  6 +DECLARE @ReturnCode INT
  7 +SELECT @ReturnCode = 0
  8 +/****** Object: JobCategory [[Uncategorized (Local)]]] Script Date: 02/24/2022 23:51:46 ******/
  9 +IF NOT EXISTS (SELECT name FROM msdb.dbo.syscategories WHERE name=N'[Uncategorized (Local)]' AND category_class=1)
  10 +BEGIN
  11 +EXEC @ReturnCode = msdb.dbo.sp_add_category @class=N'JOB', @type=N'LOCAL', @name=N'[Uncategorized (Local)]'
  12 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  13 +
  14 +END
  15 +
  16 +DECLARE @jobId BINARY(16)
  17 +EXEC @ReturnCode = msdb.dbo.sp_add_job @job_name=N'jobAtualizaTabelasSistemaComercial',
  18 + @enabled=1,
  19 + @notify_level_eventlog=0,
  20 + @notify_level_email=0,
  21 + @notify_level_netsend=0,
  22 + @notify_level_page=0,
  23 + @delete_level=0,
  24 + @description=N'No description available.',
  25 + @category_name=N'[Uncategorized (Local)]',
  26 + @owner_login_name=N'sa', @job_id = @jobId OUTPUT
  27 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  28 +/****** Object: Step [atualizarTodasTabelas] Script Date: 02/24/2022 23:51:46 ******/
  29 +EXEC @ReturnCode = msdb.dbo.sp_add_jobstep @job_id=@jobId, @step_name=N'atualizarTodasTabelas',
  30 + @step_id=1,
  31 + @cmdexec_success_code=0,
  32 + @on_success_action=1,
  33 + @on_success_step_id=0,
  34 + @on_fail_action=2,
  35 + @on_fail_step_id=0,
  36 + @retry_attempts=0,
  37 + @retry_interval=0,
  38 + @os_run_priority=0, @subsystem=N'TSQL',
  39 + @command=N'exec dbo.atualizaTabelasSistemaComercial',
  40 + @database_name=N'geosan',
  41 + @flags=0
  42 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  43 +EXEC @ReturnCode = msdb.dbo.sp_update_job @job_id = @jobId, @start_step_id = 1
  44 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  45 +EXEC @ReturnCode = msdb.dbo.sp_add_jobschedule @job_id=@jobId, @name=N'Final expediente',
  46 + @enabled=1,
  47 + @freq_type=8,
  48 + @freq_interval=62,
  49 + @freq_subday_type=1,
  50 + @freq_subday_interval=0,
  51 + @freq_relative_interval=0,
  52 + @freq_recurrence_factor=1,
  53 + @active_start_date=20220225,
  54 + @active_end_date=99991231,
  55 + @active_start_time=10000,
  56 + @active_end_time=235959,
  57 + @schedule_uid=N'2cf5b330-de94-4dbc-9071-e23bbccc9bd7'
  58 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  59 +EXEC @ReturnCode = msdb.dbo.sp_add_jobserver @job_id = @jobId, @server_name = N'(local)'
  60 +IF (@@ERROR <> 0 OR @ReturnCode <> 0) GOTO QuitWithRollback
  61 +COMMIT TRANSACTION
  62 +GOTO EndSave
  63 +QuitWithRollback:
  64 + IF (@@TRANCOUNT > 0) ROLLBACK TRANSACTION
  65 +EndSave:
  66 +
  67 +GO
0 68 \ No newline at end of file
... ...
db/SqlServer/procedures/atualizaClientesDoSistemaComercial.sql 0 → 100644
... ... @@ -0,0 +1,27 @@
  1 +USE [geosan]
  2 +GO
  3 +/****** Object: StoredProcedure [dbo].[atualizaClientesDoSistemaComercial] Script Date: 02/24/2022 17:33:50 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +-- =============================================
  9 +-- Author: José Maria Villac Pinheiro
  10 +-- Create date: 24/02/2022
  11 +-- Description: Atualiza a tabela com os dados so sistema comercial, com o objetivo do sistema rodar maisr rapidamente
  12 +-- NXGS_V_LIG_COMERCIAL_CONEXAO - é a vista conectada diretamente ao sistema comercial
  13 +-- =============================================
  14 +ALTER PROCEDURE [dbo].[atualizaClientesDoSistemaComercial]
  15 +AS
  16 +BEGIN
  17 + IF OBJECT_ID ('dbo.NXGS_V_LIG_COMERCIAL') IS NOT NULL
  18 + BEGIN
  19 + DROP TABLE [dbo].[NXGS_V_LIG_COMERCIAL];
  20 + SELECT * INTO [dbo].[NXGS_V_LIG_COMERCIAL] FROM [dbo].[NXGS_V_LIG_COMERCIAL_CONEXAO];
  21 + END
  22 + ELSE
  23 + BEGIN
  24 + SELECT * INTO [dbo].[NXGS_V_LIG_COMERCIAL] FROM [dbo].[NXGS_V_LIG_COMERCIAL_CONEXAO];
  25 + END
  26 + SET NOCOUNT ON;
  27 +END
... ...
db/SqlServer/procedures/atualizaConsumo.sql 0 → 100644
... ... @@ -0,0 +1,26 @@
  1 +USE [geosan]
  2 +GO
  3 +/****** Object: StoredProcedure [dbo].[atualizaConsumoMedio] Script Date: 02/24/2022 17:38:51 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +-- =============================================
  9 +-- Author: José Maria Villac Pinheiro
  10 +-- Create date: 24/02/2022
  11 +-- Description: Atualiza a tabela com os dados so sistema comercial, com o objetivo do sistema rodar maisr rapidamente
  12 +-- =============================================
  13 +ALTER PROCEDURE [dbo].[atualizaConsumoMedio]
  14 +AS
  15 +BEGIN
  16 + IF OBJECT_ID ('dbo.NXGS_V_LIG_COM_CONSUMO_MEDIO') IS NOT NULL
  17 + BEGIN
  18 + DROP TABLE [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO];
  19 + SELECT * INTO [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO] FROM [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO_CONEXAO];
  20 + END
  21 + ELSE
  22 + BEGIN
  23 + SELECT * INTO [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO] FROM [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO_CONEXAO];
  24 + END
  25 + SET NOCOUNT ON;
  26 +END
0 27 \ No newline at end of file
... ...
db/SqlServer/procedures/atualizaConsumoMedio.sql 0 → 100644
... ... @@ -0,0 +1,26 @@
  1 +USE [geosan]
  2 +GO
  3 +/****** Object: StoredProcedure [dbo].[atualizaConsumoMedio] Script Date: 02/24/2022 17:38:51 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +-- =============================================
  9 +-- Author: José Maria Villac Pinheiro
  10 +-- Create date: 24/02/2022
  11 +-- Description: Atualiza a tabela com os dados so sistema comercial, com o objetivo do sistema rodar maisr rapidamente
  12 +-- =============================================
  13 +ALTER PROCEDURE [dbo].[atualizaConsumoMedio]
  14 +AS
  15 +BEGIN
  16 + IF OBJECT_ID ('dbo.NXGS_V_LIG_COM_CONSUMO_MEDIO') IS NOT NULL
  17 + BEGIN
  18 + DROP TABLE [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO];
  19 + SELECT * INTO [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO] FROM [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO_CONEXAO];
  20 + END
  21 + ELSE
  22 + BEGIN
  23 + SELECT * INTO [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO] FROM [dbo].[NXGS_V_LIG_COM_CONSUMO_MEDIO_CONEXAO];
  24 + END
  25 + SET NOCOUNT ON;
  26 +END
0 27 \ No newline at end of file
... ...
db/SqlServer/procedures/atualizaTabelasSistemaComercial.sql 0 → 100644
... ... @@ -0,0 +1,20 @@
  1 +USE [geosan]
  2 +GO
  3 +/****** Object: StoredProcedure [dbo].[atualizaTabelasSistemaComercial] Script Date: 02/24/2022 23:02:08 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +-- =============================================
  9 +-- Author: José Maria Villac Pinheiro
  10 +-- Create date: 24/02/2022
  11 +-- Description: Atualiza as tabelas com os dados so sistema comercial, com o objetivo do sistema rodar maisr rapidamente
  12 +-- =============================================
  13 +ALTER PROCEDURE [dbo].[atualizaTabelasSistemaComercial]
  14 +AS
  15 +BEGIN
  16 + EXEC dbo.atualizaClientesDoSistemaComercial;
  17 + EXEC dbo.atualizaConsumoMedio;
  18 + EXEC dbo.atualizaConsumo;
  19 + SET NOCOUNT ON;
  20 +END
0 21 \ No newline at end of file
... ...
install/GeraSetupGeoSan/Codigo Gerador Instalador Geosan com TerraComponents.iss
1 1 #define SetupBaseName "SetupGeoSan-v."
2   -#define AppVersionFile "08.02.00"
  2 +#define AppVersionFile "08.02.01"
3 3  
4 4 [Setup]
5 5 AppName=GeoSan
... ...
trunk/Modules/Global.bas
... ... @@ -201,7 +201,7 @@ Public Sub Main()
201 201 End If
202 202 'Configura a versão atual do GeoSan
203 203 Versao_Geo = App.Major & "." & App.Minor & "." & App.Revision
204   - Versao_Geo = "08.02.00"
  204 + Versao_Geo = "08.02.01"
205 205 glo.diretorioGeoSan = App.path 'salva globalmente o caminho onde encontra-se o GeoSan.exe
206 206 SaveLoadGlobalData glo.diretorioGeoSan + "/controles/variaveisGlobais.txt", True 'salva em um arquivo todas as variáveis globais para poderem ser acessadas por outras aplicações
207 207 connn = ""
... ...
trunk/classes/CIntBilinear.cls
... ... @@ -50,7 +50,7 @@ Trata_Erro:
50 50 If Err.Number = 0 Or Err.Number = 20 Then
51 51 Resume Next
52 52 Else
53   - ErroUsuario.Registra "CIntBilinear", "CalcInterpolacao - divisão por zero no MDT", CStr(Err.Number), CStr(Err.Description), True, glo.enviaEmails
  53 + ErroUsuario.Registra "CIntBilinear", "CalcInterpolacao - divisão por zero no MDT", CStr(Err.Number), CStr(Err.Description), False, glo.enviaEmails
54 54 End If
55 55 End Function
56 56  
... ...