Commit c2463b5bf4fa4fe8256190e9c211a0813a675f6e

Authored by José Maria Villac Pinheiro
1 parent 5305652e
Exists in master

Alterados nomes dos arquivos para retirar acentos e manter compatibilidade com Mac

db/SqlServer/03 - Criacao do Banco Importacao da Base de Dados SQL Server - A.doc 0 → 100644
No preview for this file type
db/SqlServer/03 - Criacao do Banco Importação da Base de Dados SQL Server - A.doc
No preview for this file type
db/SqlServer/20170824162400-Historico_modificacoes_banco_dados_geosan-v.7.4.0 - Copia.txt 0 → 100644
@@ -0,0 +1,173 @@ @@ -0,0 +1,173 @@
  1 +USE [nome_do_banco_de_dados]
  2 +GO
  3 +
  4 +/****** Object: Table [dbo].[GS_NOS] Script Date: 08/24/2017 16:07:17 ******/
  5 +SET ANSI_NULLS ON
  6 +GO
  7 +
  8 +SET QUOTED_IDENTIFIER ON
  9 +GO
  10 +
  11 +SET ANSI_PADDING ON
  12 +GO
  13 +
  14 +CREATE TABLE [dbo].[GS_NOS](
  15 + [object_id_] [nvarchar](50) NOT NULL,
  16 + [idtipo] [int] NULL,
  17 + [idsubtipo] [int] NULL,
  18 + [valor] [varchar](50) NULL,
  19 + [estado] [int] NULL,
  20 + [localiza] [int] NULL,
  21 + [cota] [float] NULL,
  22 + [notacao] [nvarchar](50) NULL,
  23 + [demanda] [float] NULL,
  24 + [datainst] [varchar](50) NULL,
  25 + [descric] [varchar](25) NULL,
  26 + [especif] [varchar](50) NULL,
  27 + [x] [float] NULL,
  28 + [y] [float] NULL
  29 +) ON [PRIMARY]
  30 +
  31 +GO
  32 +
  33 +SET ANSI_PADDING OFF
  34 +GO
  35 +
  36 +USE [nome_do_banco_de_dados]
  37 +GO
  38 +
  39 +/****** Object: Table [dbo].[GS_REDES] Script Date: 08/24/2017 16:09:36 ******/
  40 +SET ANSI_NULLS ON
  41 +GO
  42 +
  43 +SET QUOTED_IDENTIFIER ON
  44 +GO
  45 +
  46 +SET ANSI_PADDING ON
  47 +GO
  48 +
  49 +CREATE TABLE [dbo].[GS_REDES](
  50 + [object_id_] [nvarchar](255) NOT NULL,
  51 + [idtipo] [int] NULL,
  52 + [tiporede] [varchar](25) NULL,
  53 + [especifi] [varchar](100) NULL,
  54 + [altinic] [float] NULL,
  55 + [altfinal] [float] NULL,
  56 + [profinic] [float] NULL,
  57 + [proffin] [float] NULL,
  58 + [diamint] [varchar](25) NULL,
  59 + [diamext] [varchar](25) NULL,
  60 + [noinic] [int] NULL,
  61 + [nofinal] [int] NULL,
  62 + [espessur] [float] NULL,
  63 + [material] [int] NULL,
  64 + [matnome] [nvarchar](50) NOT NULL,
  65 + [comprim] [float] NULL,
  66 + [compcalc] [float] NULL,
  67 + [forneced] [int] NULL,
  68 + [forempre] [nvarchar](40) NOT NULL,
  69 + [localiza] [int] NULL,
  70 + [locanome] [nvarchar](25) NOT NULL,
  71 + [estado] [int] NULL,
  72 + [estnome] [nvarchar](25) NOT NULL,
  73 + [validinf] [int] NULL,
  74 + [rugosid] [float] NOT NULL,
  75 + [setor] [float] NOT NULL,
  76 + [datainst] [varchar](25) NULL,
  77 + [ladorua] [smallint] NULL,
  78 + [ladodesc] [varchar](50) NOT NULL,
  79 + [distdiv] [numeric](18, 2) NULL,
  80 + [problema] [smallint] NULL,
  81 + [usuario] [varchar](50) NULL,
  82 + [datausu] [varchar](50) NULL,
  83 + [data] [varchar](25) NOT NULL,
  84 + [fabrican] [numeric](18, 0) NULL,
  85 + [fabrnome] [nvarchar](40) NOT NULL,
  86 + [LINE_ID] [int] NULL,
  87 + [txtacm] [varchar](50) NULL,
  88 + [txtab] [varchar](50) NULL,
  89 + [angulol] [float] NULL,
  90 + [txtabl1] [varchar](50) NULL,
  91 + [txtabl2] [varchar](50) NULL
  92 +) ON [PRIMARY]
  93 +
  94 +GO
  95 +
  96 +SET ANSI_PADDING OFF
  97 +GO
  98 +
  99 +USE [nome_do_banco_de_dados]
  100 +GO
  101 +
  102 +/****** Object: Table [dbo].[GS_RAMAIS] Script Date: 08/24/2017 16:10:44 ******/
  103 +SET ANSI_NULLS ON
  104 +GO
  105 +
  106 +SET QUOTED_IDENTIFIER ON
  107 +GO
  108 +
  109 +SET ANSI_PADDING ON
  110 +GO
  111 +
  112 +CREATE TABLE [dbo].[GS_RAMAIS](
  113 + [object_id_] [nvarchar](255) NULL,
  114 + [objidtre] [nvarchar](255) NULL,
  115 + [codlog] [int] NULL,
  116 + [distTest] [numeric](18, 2) NULL,
  117 + [distLado] [numeric](18, 2) NULL,
  118 + [compram] [numeric](18, 2) NULL,
  119 + [profram] [numeric](18, 2) NULL,
  120 + [poslote] [int] NULL,
  121 + [id] [int] NOT NULL,
  122 + [datalog] [varchar](30) NULL,
  123 + [usulog] [varchar](30) NULL
  124 +) ON [PRIMARY]
  125 +
  126 +GO
  127 +
  128 +SET ANSI_PADDING OFF
  129 +GO
  130 +
  131 +USE [nome_do_banco_de_dados]
  132 +GO
  133 +
  134 +/****** Object: Table [dbo].[GS_CONSUMIDORES] Script Date: 08/24/2017 16:12:58 ******/
  135 +SET ANSI_NULLS ON
  136 +GO
  137 +
  138 +SET QUOTED_IDENTIFIER ON
  139 +GO
  140 +
  141 +CREATE TABLE [dbo].[GS_CONSUMIDORES](
  142 + [OBJECT_ID_] [nvarchar](250) NULL,
  143 + [NRO_LIG] [nvarchar](50) NULL,
  144 + [NROL_SDV] [nvarchar](50) NULL,
  145 + [INSCLOTE] [nvarchar](50) NULL,
  146 + [AUTO] [nvarchar](10) NULL,
  147 + [CONS_LPS] [nvarchar](24) NULL,
  148 + [TIPO] [nvarchar](20) NULL,
  149 + [COD_LOG] [nvarchar](30) NULL,
  150 + [ENDERECO] [nvarchar](250) NULL,
  151 + [NUM_CASA] [nvarchar](15) NULL,
  152 + [COMPLLOG] [nvarchar](60) NULL,
  153 + [BAIRRO] [nvarchar](150) NULL,
  154 + [HIDROM] [nvarchar](30) NULL,
  155 + [COD_CONS] [nvarchar](11) NULL,
  156 + [CODCONSDV] [nvarchar](11) NULL,
  157 + [CONSUM] [nvarchar](150) NULL,
  158 + [TEL_RES] [nvarchar](20) NULL,
  159 + [TEL_COM] [nvarchar](20) NULL,
  160 + [ECONOM] [nvarchar](10) NULL,
  161 + [DATAIMP] [nvarchar](30) NULL,
  162 + [DATAIMPE] [nvarchar](30) NULL,
  163 + [ROTALEIT] [nvarchar](50) NULL,
  164 + [GRUPOL] [nvarchar](10) NULL,
  165 + [ROTLEIT] [nvarchar](10) NULL,
  166 + [SEQLEI] [nvarchar](10) NULL,
  167 + [CONSFAT] [nvarchar](15) NULL,
  168 + [CONMED] [nvarchar](15) NULL,
  169 + [MES] [nvarchar](2) NULL,
  170 + [ANO] [nvarchar](2) NULL
  171 +) ON [PRIMARY]
  172 +
  173 +GO
0 \ No newline at end of file 174 \ No newline at end of file
db/SqlServer/20170824162400-Historico_modificacoes_banco_dados_geosan-v.7.4.0 - Cópia.txt
@@ -1,173 +0,0 @@ @@ -1,173 +0,0 @@
1 -USE [nome_do_banco_de_dados]  
2 -GO  
3 -  
4 -/****** Object: Table [dbo].[GS_NOS] Script Date: 08/24/2017 16:07:17 ******/  
5 -SET ANSI_NULLS ON  
6 -GO  
7 -  
8 -SET QUOTED_IDENTIFIER ON  
9 -GO  
10 -  
11 -SET ANSI_PADDING ON  
12 -GO  
13 -  
14 -CREATE TABLE [dbo].[GS_NOS](  
15 - [object_id_] [nvarchar](50) NOT NULL,  
16 - [idtipo] [int] NULL,  
17 - [idsubtipo] [int] NULL,  
18 - [valor] [varchar](50) NULL,  
19 - [estado] [int] NULL,  
20 - [localiza] [int] NULL,  
21 - [cota] [float] NULL,  
22 - [notacao] [nvarchar](50) NULL,  
23 - [demanda] [float] NULL,  
24 - [datainst] [varchar](50) NULL,  
25 - [descric] [varchar](25) NULL,  
26 - [especif] [varchar](50) NULL,  
27 - [x] [float] NULL,  
28 - [y] [float] NULL  
29 -) ON [PRIMARY]  
30 -  
31 -GO  
32 -  
33 -SET ANSI_PADDING OFF  
34 -GO  
35 -  
36 -USE [nome_do_banco_de_dados]  
37 -GO  
38 -  
39 -/****** Object: Table [dbo].[GS_REDES] Script Date: 08/24/2017 16:09:36 ******/  
40 -SET ANSI_NULLS ON  
41 -GO  
42 -  
43 -SET QUOTED_IDENTIFIER ON  
44 -GO  
45 -  
46 -SET ANSI_PADDING ON  
47 -GO  
48 -  
49 -CREATE TABLE [dbo].[GS_REDES](  
50 - [object_id_] [nvarchar](255) NOT NULL,  
51 - [idtipo] [int] NULL,  
52 - [tiporede] [varchar](25) NULL,  
53 - [especifi] [varchar](100) NULL,  
54 - [altinic] [float] NULL,  
55 - [altfinal] [float] NULL,  
56 - [profinic] [float] NULL,  
57 - [proffin] [float] NULL,  
58 - [diamint] [varchar](25) NULL,  
59 - [diamext] [varchar](25) NULL,  
60 - [noinic] [int] NULL,  
61 - [nofinal] [int] NULL,  
62 - [espessur] [float] NULL,  
63 - [material] [int] NULL,  
64 - [matnome] [nvarchar](50) NOT NULL,  
65 - [comprim] [float] NULL,  
66 - [compcalc] [float] NULL,  
67 - [forneced] [int] NULL,  
68 - [forempre] [nvarchar](40) NOT NULL,  
69 - [localiza] [int] NULL,  
70 - [locanome] [nvarchar](25) NOT NULL,  
71 - [estado] [int] NULL,  
72 - [estnome] [nvarchar](25) NOT NULL,  
73 - [validinf] [int] NULL,  
74 - [rugosid] [float] NOT NULL,  
75 - [setor] [float] NOT NULL,  
76 - [datainst] [varchar](25) NULL,  
77 - [ladorua] [smallint] NULL,  
78 - [ladodesc] [varchar](50) NOT NULL,  
79 - [distdiv] [numeric](18, 2) NULL,  
80 - [problema] [smallint] NULL,  
81 - [usuario] [varchar](50) NULL,  
82 - [datausu] [varchar](50) NULL,  
83 - [data] [varchar](25) NOT NULL,  
84 - [fabrican] [numeric](18, 0) NULL,  
85 - [fabrnome] [nvarchar](40) NOT NULL,  
86 - [LINE_ID] [int] NULL,  
87 - [txtacm] [varchar](50) NULL,  
88 - [txtab] [varchar](50) NULL,  
89 - [angulol] [float] NULL,  
90 - [txtabl1] [varchar](50) NULL,  
91 - [txtabl2] [varchar](50) NULL  
92 -) ON [PRIMARY]  
93 -  
94 -GO  
95 -  
96 -SET ANSI_PADDING OFF  
97 -GO  
98 -  
99 -USE [nome_do_banco_de_dados]  
100 -GO  
101 -  
102 -/****** Object: Table [dbo].[GS_RAMAIS] Script Date: 08/24/2017 16:10:44 ******/  
103 -SET ANSI_NULLS ON  
104 -GO  
105 -  
106 -SET QUOTED_IDENTIFIER ON  
107 -GO  
108 -  
109 -SET ANSI_PADDING ON  
110 -GO  
111 -  
112 -CREATE TABLE [dbo].[GS_RAMAIS](  
113 - [object_id_] [nvarchar](255) NULL,  
114 - [objidtre] [nvarchar](255) NULL,  
115 - [codlog] [int] NULL,  
116 - [distTest] [numeric](18, 2) NULL,  
117 - [distLado] [numeric](18, 2) NULL,  
118 - [compram] [numeric](18, 2) NULL,  
119 - [profram] [numeric](18, 2) NULL,  
120 - [poslote] [int] NULL,  
121 - [id] [int] NOT NULL,  
122 - [datalog] [varchar](30) NULL,  
123 - [usulog] [varchar](30) NULL  
124 -) ON [PRIMARY]  
125 -  
126 -GO  
127 -  
128 -SET ANSI_PADDING OFF  
129 -GO  
130 -  
131 -USE [nome_do_banco_de_dados]  
132 -GO  
133 -  
134 -/****** Object: Table [dbo].[GS_CONSUMIDORES] Script Date: 08/24/2017 16:12:58 ******/  
135 -SET ANSI_NULLS ON  
136 -GO  
137 -  
138 -SET QUOTED_IDENTIFIER ON  
139 -GO  
140 -  
141 -CREATE TABLE [dbo].[GS_CONSUMIDORES](  
142 - [OBJECT_ID_] [nvarchar](250) NULL,  
143 - [NRO_LIG] [nvarchar](50) NULL,  
144 - [NROL_SDV] [nvarchar](50) NULL,  
145 - [INSCLOTE] [nvarchar](50) NULL,  
146 - [AUTO] [nvarchar](10) NULL,  
147 - [CONS_LPS] [nvarchar](24) NULL,  
148 - [TIPO] [nvarchar](20) NULL,  
149 - [COD_LOG] [nvarchar](30) NULL,  
150 - [ENDERECO] [nvarchar](250) NULL,  
151 - [NUM_CASA] [nvarchar](15) NULL,  
152 - [COMPLLOG] [nvarchar](60) NULL,  
153 - [BAIRRO] [nvarchar](150) NULL,  
154 - [HIDROM] [nvarchar](30) NULL,  
155 - [COD_CONS] [nvarchar](11) NULL,  
156 - [CODCONSDV] [nvarchar](11) NULL,  
157 - [CONSUM] [nvarchar](150) NULL,  
158 - [TEL_RES] [nvarchar](20) NULL,  
159 - [TEL_COM] [nvarchar](20) NULL,  
160 - [ECONOM] [nvarchar](10) NULL,  
161 - [DATAIMP] [nvarchar](30) NULL,  
162 - [DATAIMPE] [nvarchar](30) NULL,  
163 - [ROTALEIT] [nvarchar](50) NULL,  
164 - [GRUPOL] [nvarchar](10) NULL,  
165 - [ROTLEIT] [nvarchar](10) NULL,  
166 - [SEQLEI] [nvarchar](10) NULL,  
167 - [CONSFAT] [nvarchar](15) NULL,  
168 - [CONMED] [nvarchar](15) NULL,  
169 - [MES] [nvarchar](2) NULL,  
170 - [ANO] [nvarchar](2) NULL  
171 -) ON [PRIMARY]  
172 -  
173 -GO  
174 \ No newline at end of file 0 \ No newline at end of file
sql/20151126132800-querie para inserir novos parametros.sql 0 → 100644
@@ -0,0 +1,95 @@ @@ -0,0 +1,95 @@
  1 +USE [ArturNogueira-B]
  2 +
  3 +
  4 +/* insere parâmetros de bomba */
  5 +
  6 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  7 +(3, 1, 'POTÊNCIA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  8 +
  9 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  10 +(3, 2, 'CARGA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  11 +
  12 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  13 +(3, 3, 'VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  14 +
  15 +/* insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  16 +(3, 4, 'REND_VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL) */
  17 +
  18 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  19 +(3, 4, 'RENDIMENTO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  20 +
  21 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  22 +(3, 5, 'CURVA DA BOMBA', 'False', 0.0000, 0.0000, 0, 2, NULL)
  23 +
  24 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  25 +(3, 6, 'CURVA DE REND', 'False', 0.0000, 0.0000, 0, 2, NULL)
  26 +
  27 +
  28 +/* Apaga todos os metadados de bomba */
  29 +
  30 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 1 and Description_ = 'POTÊNCIA'
  31 +
  32 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 2 and Description_ = 'CARGA'
  33 +
  34 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 3 and Description_ = 'VAZÃO'
  35 +
  36 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 4 and Description_ = 'RENDIMENTO'
  37 +
  38 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 5 and Description_ = 'CURVA DA BOMBA'
  39 +
  40 +delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 6 and Description_ = 'CURVA DE REND'
  41 +
  42 +/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
  43 +
  44 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 1
  45 +
  46 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 2
  47 +
  48 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 3
  49 +
  50 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 4
  51 +
  52 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 5
  53 +
  54 +delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 6
  55 +
  56 +/* insere parâmetros de um RNV */
  57 +
  58 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  59 +(28, 1, 'ALT INICIAL', 'False', 0.0000, 0.0000, 0, 2, NULL)
  60 +
  61 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  62 +(28, 2, 'ALT MIN', 'False', 0.0000, 0.0000, 0, 2, NULL)
  63 +
  64 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  65 +(28, 3, 'ALT MAX', 'False', 0.0000, 0.0000, 0, 2, NULL)
  66 +
  67 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  68 +(28, 4, 'DIÂMETRO', 'False', 0.0000, 0.0000, 0, 2, NULL)
  69 +
  70 +insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values
  71 +(28, 5, 'CURVA DE VOLUME', 'False', 0.0000, 0.0000, 0, 2, NULL)
  72 +
  73 +/* Apaga todos os metadados de RNV */
  74 +
  75 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 1 and Description_ = 'ALT INICIAL'
  76 +
  77 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 2 and Description_ = 'ALT MIN'
  78 +
  79 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 3 and Description_ = 'ALT MAX'
  80 +
  81 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'DIÂMETRO'
  82 +
  83 +delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'CURVA DE VOLUME'
  84 +
  85 +/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */
  86 +
  87 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 1
  88 +
  89 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 2
  90 +
  91 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 3
  92 +
  93 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 4
  94 +
  95 +delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 5
0 \ No newline at end of file 96 \ No newline at end of file
sql/20151126132800-querie para inserir novos parâmetros.sql
@@ -1,95 +0,0 @@ @@ -1,95 +0,0 @@
1 -USE [ArturNogueira-B]  
2 -  
3 -  
4 -/* insere parâmetros de bomba */  
5 -  
6 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
7 -(3, 1, 'POTÊNCIA', 'False', 0.0000, 0.0000, 0, 2, NULL)  
8 -  
9 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
10 -(3, 2, 'CARGA', 'False', 0.0000, 0.0000, 0, 2, NULL)  
11 -  
12 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
13 -(3, 3, 'VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL)  
14 -  
15 -/* insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
16 -(3, 4, 'REND_VAZÃO', 'False', 0.0000, 0.0000, 0, 2, NULL) */  
17 -  
18 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
19 -(3, 4, 'RENDIMENTO', 'False', 0.0000, 0.0000, 0, 2, NULL)  
20 -  
21 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
22 -(3, 5, 'CURVA DA BOMBA', 'False', 0.0000, 0.0000, 0, 2, NULL)  
23 -  
24 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
25 -(3, 6, 'CURVA DE REND', 'False', 0.0000, 0.0000, 0, 2, NULL)  
26 -  
27 -  
28 -/* Apaga todos os metadados de bomba */  
29 -  
30 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 1 and Description_ = 'POTÊNCIA'  
31 -  
32 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 2 and Description_ = 'CARGA'  
33 -  
34 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 3 and Description_ = 'VAZÃO'  
35 -  
36 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 4 and Description_ = 'RENDIMENTO'  
37 -  
38 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 5 and Description_ = 'CURVA DA BOMBA'  
39 -  
40 -delete from WaterComponentsSubTypes where id_Type = 3 and id_SubType = 6 and Description_ = 'CURVA DE REND'  
41 -  
42 -/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */  
43 -  
44 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 1  
45 -  
46 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 2  
47 -  
48 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 3  
49 -  
50 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 4  
51 -  
52 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 5  
53 -  
54 -delete from WATERCOMPONENTSDATA where ID_TYPE = 3 and ID_SUBTYPE = 6  
55 -  
56 -/* insere parâmetros de um RNV */  
57 -  
58 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
59 -(28, 1, 'ALT INICIAL', 'False', 0.0000, 0.0000, 0, 2, NULL)  
60 -  
61 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
62 -(28, 2, 'ALT MIN', 'False', 0.0000, 0.0000, 0, 2, NULL)  
63 -  
64 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
65 -(28, 3, 'ALT MAX', 'False', 0.0000, 0.0000, 0, 2, NULL)  
66 -  
67 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
68 -(28, 4, 'DIÂMETRO', 'False', 0.0000, 0.0000, 0, 2, NULL)  
69 -  
70 -insert into WaterComponentsSubTypes (id_Type, id_SubType, Description_, Selection_, Max_, Min_, DefaultValue, DataType, EPAREF) values  
71 -(28, 5, 'CURVA DE VOLUME', 'False', 0.0000, 0.0000, 0, 2, NULL)  
72 -  
73 -/* Apaga todos os metadados de RNV */  
74 -  
75 -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 1 and Description_ = 'ALT INICIAL'  
76 -  
77 -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 2 and Description_ = 'ALT MIN'  
78 -  
79 -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 3 and Description_ = 'ALT MAX'  
80 -  
81 -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'DIÂMETRO'  
82 -  
83 -delete from WaterComponentsSubTypes where id_Type = 28 and id_SubType = 4 and Description_ = 'CURVA DE VOLUME'  
84 -  
85 -/* Apaga todos os dados cadastrados no GeoSan das bombas (TODOS) */  
86 -  
87 -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 1  
88 -  
89 -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 2  
90 -  
91 -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 3  
92 -  
93 -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 4  
94 -  
95 -delete from WATERCOMPONENTSDATA where ID_TYPE = 28 and ID_SUBTYPE = 5  
96 \ No newline at end of file 0 \ No newline at end of file
sql/20160209175500-GeoSan 7.0.43 - parametros novos para exportacao para EPANET.sql 0 → 100644
@@ -0,0 +1,198 @@ @@ -0,0 +1,198 @@
  1 +/* Para criar as tabelas */
  2 +
  3 +USE [ArturNogueira-B]
  4 +
  5 +SET ANSI_NULLS ON
  6 +GO
  7 +SET QUOTED_IDENTIFIER ON
  8 +GO
  9 +SET ANSI_PADDING ON
  10 +GO
  11 +CREATE TABLE XXXX
  12 +GO
  13 +SET ANSI_PADDING OFF
  14 +GO
  15 +
  16 +
  17 +/* insere os tipos de componentes os quais um nó pode vir a ser */
  18 +
  19 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
  20 +
  21 +CREATE TABLE [dbo].[WaterComponentsTypes](
  22 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  23 + [Description_] [varchar](25) NULL,
  24 + [Specification_] [varchar](100) NULL
  25 +) ON [PRIMARY]
  26 +
  27 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  63 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  64 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  65 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  66 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  67 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  68 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  69 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  70 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  71 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  72 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  73 +
  74 +
  75 +/* Apaga todos os metadados dos nós */
  76 +
  77 +delete from WaterComponentsTypes where id_Type = 0
  78 +delete from WaterComponentsTypes where id_Type = 1
  79 +delete from WaterComponentsTypes where id_Type = 2
  80 +delete from WaterComponentsTypes where id_Type = 3
  81 +delete from WaterComponentsTypes where id_Type = 4
  82 +delete from WaterComponentsTypes where id_Type = 5
  83 +delete from WaterComponentsTypes where id_Type = 6
  84 +delete from WaterComponentsTypes where id_Type = 7
  85 +delete from WaterComponentsTypes where id_Type = 8
  86 +delete from WaterComponentsTypes where id_Type = 9
  87 +delete from WaterComponentsTypes where id_Type = 10
  88 +delete from WaterComponentsTypes where id_Type = 11
  89 +delete from WaterComponentsTypes where id_Type = 12
  90 +delete from WaterComponentsTypes where id_Type = 13
  91 +delete from WaterComponentsTypes where id_Type = 14
  92 +delete from WaterComponentsTypes where id_Type = 15
  93 +delete from WaterComponentsTypes where id_Type = 16
  94 +delete from WaterComponentsTypes where id_Type = 17
  95 +delete from WaterComponentsTypes where id_Type = 17
  96 +delete from WaterComponentsTypes where id_Type = 19
  97 +delete from WaterComponentsTypes where id_Type = 20
  98 +delete from WaterComponentsTypes where id_Type = 21
  99 +delete from WaterComponentsTypes where id_Type = 22
  100 +delete from WaterComponentsTypes where id_Type = 23
  101 +delete from WaterComponentsTypes where id_Type = 24
  102 +delete from WaterComponentsTypes where id_Type = 25
  103 +delete from WaterComponentsTypes where id_Type = 26
  104 +delete from WaterComponentsTypes where id_Type = 27
  105 +delete from WaterComponentsTypes where id_Type = 28
  106 +delete from WaterComponentsTypes where id_Type = 29
  107 +delete from WaterComponentsTypes where id_Type = 30
  108 +delete from WaterComponentsTypes where id_Type = 31
  109 +delete from WaterComponentsTypes where id_Type = 32
  110 +delete from WaterComponentsTypes where id_Type = 33
  111 +delete from WaterComponentsTypes where id_Type = 34
  112 +delete from WaterComponentsTypes where id_Type = 35
  113 +delete from WaterComponentsTypes where id_Type = 36
  114 +delete from WaterComponentsTypes where id_Type = 37
  115 +delete from WaterComponentsTypes where id_Type = 38
  116 +delete from WaterComponentsTypes where id_Type = 39
  117 +delete from WaterComponentsTypes where id_Type = 40
  118 +delete from WaterComponentsTypes where id_Type = 41
  119 +delete from WaterComponentsTypes where id_Type = 42
  120 +delete from WaterComponentsTypes where id_Type = 43
  121 +delete from WaterComponentsTypes where id_Type = 44
  122 +delete from WaterComponentsTypes where id_Type = 45
  123 +delete from WaterComponentsTypes where id_Type = 46
  124 +
  125 +/* insere parâmetros de todos subtipos */
  126 +
  127 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  128 + [id_Type] [int] NOT NULL,
  129 + [id_SubType] [int] NOT NULL,
  130 + [Description_] [varchar](50) NULL,
  131 + [Selection_] [bit] NOT NULL,
  132 + [Max_] [numeric](18, 4) NULL,
  133 + [Min_] [numeric](18, 4) NULL,
  134 + [DefaultValue] [nvarchar](50) NOT NULL,
  135 + [DataType] [int] NULL,
  136 + [EPAREF] [nvarchar](10) NULL
  137 +) ON [PRIMARY]
  138 +
  139 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  140 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  141 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  142 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  143 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  144 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  145 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  146 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  147 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  148 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  149 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  150 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  151 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  152 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  153 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  154 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  155 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  156 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  157 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  158 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  159 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  160 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  161 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  162 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  163 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  164 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  165 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  166 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  167 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  168 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  169 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  170 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  171 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  172 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  173 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  174 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  175 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  176 +
  177 +/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
  178 +
  179 +CREATE TABLE [dbo].[WaterComponentsSelections](
  180 + [id_Type] [int] NOT NULL,
  181 + [id_SubType] [int] NOT NULL,
  182 + [Option_] [varchar](25) NOT NULL,
  183 + [Value_] [nvarchar](50) NOT NULL,
  184 + [Description_] [varchar](30) NULL
  185 +) ON [PRIMARY]
  186 +
  187 +GO
  188 +
  189 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  190 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  191 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  192 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  193 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  194 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  195 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  196 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  197 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
  198 +
sql/20160209175500-GeoSan 7.0.43 - parâmetros novos para exportação para EPANET.sql
@@ -1,198 +0,0 @@ @@ -1,198 +0,0 @@
1 -/* Para criar as tabelas */  
2 -  
3 -USE [ArturNogueira-B]  
4 -  
5 -SET ANSI_NULLS ON  
6 -GO  
7 -SET QUOTED_IDENTIFIER ON  
8 -GO  
9 -SET ANSI_PADDING ON  
10 -GO  
11 -CREATE TABLE XXXX  
12 -GO  
13 -SET ANSI_PADDING OFF  
14 -GO  
15 -  
16 -  
17 -/* insere os tipos de componentes os quais um nó pode vir a ser */  
18 -  
19 -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/  
20 -  
21 -CREATE TABLE [dbo].[WaterComponentsTypes](  
22 - [id_Type] [int] IDENTITY(1,1) NOT NULL,  
23 - [Description_] [varchar](25) NULL,  
24 - [Specification_] [varchar](100) NULL  
25 -) ON [PRIMARY]  
26 -  
27 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON  
28 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')  
29 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')  
30 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')  
31 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')  
32 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')  
33 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')  
34 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')  
35 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')  
36 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')  
37 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')  
38 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')  
39 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')  
40 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')  
41 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')  
42 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')  
43 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')  
44 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')  
45 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')  
46 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')  
47 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')  
48 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')  
49 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')  
50 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')  
51 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')  
52 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')  
53 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')  
54 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')  
55 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')  
56 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')  
57 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')  
58 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')  
59 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')  
60 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')  
61 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')  
62 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')  
63 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')  
64 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')  
65 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')  
66 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')  
67 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')  
68 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')  
69 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')  
70 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')  
71 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')  
72 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF  
73 -  
74 -  
75 -/* Apaga todos os metadados dos nós */  
76 -  
77 -delete from WaterComponentsTypes where id_Type = 0  
78 -delete from WaterComponentsTypes where id_Type = 1  
79 -delete from WaterComponentsTypes where id_Type = 2  
80 -delete from WaterComponentsTypes where id_Type = 3  
81 -delete from WaterComponentsTypes where id_Type = 4  
82 -delete from WaterComponentsTypes where id_Type = 5  
83 -delete from WaterComponentsTypes where id_Type = 6  
84 -delete from WaterComponentsTypes where id_Type = 7  
85 -delete from WaterComponentsTypes where id_Type = 8  
86 -delete from WaterComponentsTypes where id_Type = 9  
87 -delete from WaterComponentsTypes where id_Type = 10  
88 -delete from WaterComponentsTypes where id_Type = 11  
89 -delete from WaterComponentsTypes where id_Type = 12  
90 -delete from WaterComponentsTypes where id_Type = 13  
91 -delete from WaterComponentsTypes where id_Type = 14  
92 -delete from WaterComponentsTypes where id_Type = 15  
93 -delete from WaterComponentsTypes where id_Type = 16  
94 -delete from WaterComponentsTypes where id_Type = 17  
95 -delete from WaterComponentsTypes where id_Type = 17  
96 -delete from WaterComponentsTypes where id_Type = 19  
97 -delete from WaterComponentsTypes where id_Type = 20  
98 -delete from WaterComponentsTypes where id_Type = 21  
99 -delete from WaterComponentsTypes where id_Type = 22  
100 -delete from WaterComponentsTypes where id_Type = 23  
101 -delete from WaterComponentsTypes where id_Type = 24  
102 -delete from WaterComponentsTypes where id_Type = 25  
103 -delete from WaterComponentsTypes where id_Type = 26  
104 -delete from WaterComponentsTypes where id_Type = 27  
105 -delete from WaterComponentsTypes where id_Type = 28  
106 -delete from WaterComponentsTypes where id_Type = 29  
107 -delete from WaterComponentsTypes where id_Type = 30  
108 -delete from WaterComponentsTypes where id_Type = 31  
109 -delete from WaterComponentsTypes where id_Type = 32  
110 -delete from WaterComponentsTypes where id_Type = 33  
111 -delete from WaterComponentsTypes where id_Type = 34  
112 -delete from WaterComponentsTypes where id_Type = 35  
113 -delete from WaterComponentsTypes where id_Type = 36  
114 -delete from WaterComponentsTypes where id_Type = 37  
115 -delete from WaterComponentsTypes where id_Type = 38  
116 -delete from WaterComponentsTypes where id_Type = 39  
117 -delete from WaterComponentsTypes where id_Type = 40  
118 -delete from WaterComponentsTypes where id_Type = 41  
119 -delete from WaterComponentsTypes where id_Type = 42  
120 -delete from WaterComponentsTypes where id_Type = 43  
121 -delete from WaterComponentsTypes where id_Type = 44  
122 -delete from WaterComponentsTypes where id_Type = 45  
123 -delete from WaterComponentsTypes where id_Type = 46  
124 -  
125 -/* insere parâmetros de todos subtipos */  
126 -  
127 -CREATE TABLE [dbo].[WaterComponentsSubTypes](  
128 - [id_Type] [int] NOT NULL,  
129 - [id_SubType] [int] NOT NULL,  
130 - [Description_] [varchar](50) NULL,  
131 - [Selection_] [bit] NOT NULL,  
132 - [Max_] [numeric](18, 4) NULL,  
133 - [Min_] [numeric](18, 4) NULL,  
134 - [DefaultValue] [nvarchar](50) NOT NULL,  
135 - [DataType] [int] NULL,  
136 - [EPAREF] [nvarchar](10) NULL  
137 -) ON [PRIMARY]  
138 -  
139 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')  
140 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)  
141 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')  
142 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')  
143 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
144 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
145 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
146 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')  
147 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
148 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')  
149 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')  
150 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
151 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')  
152 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')  
153 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')  
154 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
155 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
156 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
157 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
158 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
159 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
160 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')  
161 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')  
162 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')  
163 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
164 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
165 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
166 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
167 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
168 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
169 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
170 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
171 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
172 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
173 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
174 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
175 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
176 -  
177 -/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */  
178 -  
179 -CREATE TABLE [dbo].[WaterComponentsSelections](  
180 - [id_Type] [int] NOT NULL,  
181 - [id_SubType] [int] NOT NULL,  
182 - [Option_] [varchar](25) NOT NULL,  
183 - [Value_] [nvarchar](50) NOT NULL,  
184 - [Description_] [varchar](30) NULL  
185 -) ON [PRIMARY]  
186 -  
187 -GO  
188 -  
189 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')  
190 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')  
191 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')  
192 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')  
193 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')  
194 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')  
195 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')  
196 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')  
197 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')  
198 -  
sql/20160210081600-GeoSan 7.0.43 - parametros para adicionar para banco 7.0.31.sql 0 → 100644
@@ -0,0 +1,201 @@ @@ -0,0 +1,201 @@
  1 +/* Queries para os usuários que possuem a versão do banco 7.0.31 e desejem somente atualizar os metadados para rodar a versão 7.0.43 *?
  2 +
  3 +
  4 +/* Para criar as tabelas */
  5 +
  6 +USE [ArturNogueira-B]
  7 +
  8 +SET ANSI_NULLS ON
  9 +GO
  10 +SET QUOTED_IDENTIFIER ON
  11 +GO
  12 +SET ANSI_PADDING ON
  13 +GO
  14 +CREATE TABLE XXXX
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +
  19 +
  20 +/* insere os tipos de componentes os quais um nó pode vir a ser */
  21 +
  22 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/
  23 +
  24 +CREATE TABLE [dbo].[WaterComponentsTypes](
  25 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  26 + [Description_] [varchar](25) NULL,
  27 + [Specification_] [varchar](100) NULL
  28 +) ON [PRIMARY]
  29 +
  30 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  63 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  64 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  65 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  66 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  67 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  68 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  69 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  70 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  71 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  72 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  73 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  74 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  75 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  76 +
  77 +
  78 +/* Apaga todos os metadados dos nós */
  79 +
  80 +delete from WaterComponentsTypes where id_Type = 0
  81 +delete from WaterComponentsTypes where id_Type = 1
  82 +delete from WaterComponentsTypes where id_Type = 2
  83 +delete from WaterComponentsTypes where id_Type = 3
  84 +delete from WaterComponentsTypes where id_Type = 4
  85 +delete from WaterComponentsTypes where id_Type = 5
  86 +delete from WaterComponentsTypes where id_Type = 6
  87 +delete from WaterComponentsTypes where id_Type = 7
  88 +delete from WaterComponentsTypes where id_Type = 8
  89 +delete from WaterComponentsTypes where id_Type = 9
  90 +delete from WaterComponentsTypes where id_Type = 10
  91 +delete from WaterComponentsTypes where id_Type = 11
  92 +delete from WaterComponentsTypes where id_Type = 12
  93 +delete from WaterComponentsTypes where id_Type = 13
  94 +delete from WaterComponentsTypes where id_Type = 14
  95 +delete from WaterComponentsTypes where id_Type = 15
  96 +delete from WaterComponentsTypes where id_Type = 16
  97 +delete from WaterComponentsTypes where id_Type = 17
  98 +delete from WaterComponentsTypes where id_Type = 17
  99 +delete from WaterComponentsTypes where id_Type = 19
  100 +delete from WaterComponentsTypes where id_Type = 20
  101 +delete from WaterComponentsTypes where id_Type = 21
  102 +delete from WaterComponentsTypes where id_Type = 22
  103 +delete from WaterComponentsTypes where id_Type = 23
  104 +delete from WaterComponentsTypes where id_Type = 24
  105 +delete from WaterComponentsTypes where id_Type = 25
  106 +delete from WaterComponentsTypes where id_Type = 26
  107 +delete from WaterComponentsTypes where id_Type = 27
  108 +delete from WaterComponentsTypes where id_Type = 28
  109 +delete from WaterComponentsTypes where id_Type = 29
  110 +delete from WaterComponentsTypes where id_Type = 30
  111 +delete from WaterComponentsTypes where id_Type = 31
  112 +delete from WaterComponentsTypes where id_Type = 32
  113 +delete from WaterComponentsTypes where id_Type = 33
  114 +delete from WaterComponentsTypes where id_Type = 34
  115 +delete from WaterComponentsTypes where id_Type = 35
  116 +delete from WaterComponentsTypes where id_Type = 36
  117 +delete from WaterComponentsTypes where id_Type = 37
  118 +delete from WaterComponentsTypes where id_Type = 38
  119 +delete from WaterComponentsTypes where id_Type = 39
  120 +delete from WaterComponentsTypes where id_Type = 40
  121 +delete from WaterComponentsTypes where id_Type = 41
  122 +delete from WaterComponentsTypes where id_Type = 42
  123 +delete from WaterComponentsTypes where id_Type = 43
  124 +delete from WaterComponentsTypes where id_Type = 44
  125 +delete from WaterComponentsTypes where id_Type = 45
  126 +delete from WaterComponentsTypes where id_Type = 46
  127 +
  128 +/* insere parâmetros de todos subtipos */
  129 +
  130 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  131 + [id_Type] [int] NOT NULL,
  132 + [id_SubType] [int] NOT NULL,
  133 + [Description_] [varchar](50) NULL,
  134 + [Selection_] [bit] NOT NULL,
  135 + [Max_] [numeric](18, 4) NULL,
  136 + [Min_] [numeric](18, 4) NULL,
  137 + [DefaultValue] [nvarchar](50) NOT NULL,
  138 + [DataType] [int] NULL,
  139 + [EPAREF] [nvarchar](10) NULL
  140 +) ON [PRIMARY]
  141 +
  142 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  143 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  144 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  145 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  146 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  147 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  148 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  149 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  150 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  151 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  152 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  153 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  154 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  155 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  156 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  157 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  158 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  159 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  160 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  161 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  162 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  163 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  164 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  165 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  166 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  167 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  168 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  169 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  170 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  171 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  172 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  173 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  174 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  175 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  176 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  177 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  178 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  179 +
  180 +/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */
  181 +
  182 +CREATE TABLE [dbo].[WaterComponentsSelections](
  183 + [id_Type] [int] NOT NULL,
  184 + [id_SubType] [int] NOT NULL,
  185 + [Option_] [varchar](25) NOT NULL,
  186 + [Value_] [nvarchar](50) NOT NULL,
  187 + [Description_] [varchar](30) NULL
  188 +) ON [PRIMARY]
  189 +
  190 +GO
  191 +
  192 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  193 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  194 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  195 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  196 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  197 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  198 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  199 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  200 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
  201 +
sql/20160210081600-GeoSan 7.0.43 - parâmetros para adicionar para banco 7.0.31.sql
@@ -1,201 +0,0 @@ @@ -1,201 +0,0 @@
1 -/* Queries para os usuários que possuem a versão do banco 7.0.31 e desejem somente atualizar os metadados para rodar a versão 7.0.43 *?  
2 -  
3 -  
4 -/* Para criar as tabelas */  
5 -  
6 -USE [ArturNogueira-B]  
7 -  
8 -SET ANSI_NULLS ON  
9 -GO  
10 -SET QUOTED_IDENTIFIER ON  
11 -GO  
12 -SET ANSI_PADDING ON  
13 -GO  
14 -CREATE TABLE XXXX  
15 -GO  
16 -SET ANSI_PADDING OFF  
17 -GO  
18 -  
19 -  
20 -/* insere os tipos de componentes os quais um nó pode vir a ser */  
21 -  
22 -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/09/2016 18:07:15 ******/  
23 -  
24 -CREATE TABLE [dbo].[WaterComponentsTypes](  
25 - [id_Type] [int] IDENTITY(1,1) NOT NULL,  
26 - [Description_] [varchar](25) NULL,  
27 - [Specification_] [varchar](100) NULL  
28 -) ON [PRIMARY]  
29 -  
30 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON  
31 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')  
32 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')  
33 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')  
34 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')  
35 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')  
36 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')  
37 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')  
38 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')  
39 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')  
40 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')  
41 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')  
42 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')  
43 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')  
44 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')  
45 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')  
46 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')  
47 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')  
48 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')  
49 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')  
50 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')  
51 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')  
52 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')  
53 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')  
54 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')  
55 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')  
56 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')  
57 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')  
58 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')  
59 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')  
60 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')  
61 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')  
62 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')  
63 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')  
64 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')  
65 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')  
66 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')  
67 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')  
68 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')  
69 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')  
70 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')  
71 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')  
72 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')  
73 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')  
74 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')  
75 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF  
76 -  
77 -  
78 -/* Apaga todos os metadados dos nós */  
79 -  
80 -delete from WaterComponentsTypes where id_Type = 0  
81 -delete from WaterComponentsTypes where id_Type = 1  
82 -delete from WaterComponentsTypes where id_Type = 2  
83 -delete from WaterComponentsTypes where id_Type = 3  
84 -delete from WaterComponentsTypes where id_Type = 4  
85 -delete from WaterComponentsTypes where id_Type = 5  
86 -delete from WaterComponentsTypes where id_Type = 6  
87 -delete from WaterComponentsTypes where id_Type = 7  
88 -delete from WaterComponentsTypes where id_Type = 8  
89 -delete from WaterComponentsTypes where id_Type = 9  
90 -delete from WaterComponentsTypes where id_Type = 10  
91 -delete from WaterComponentsTypes where id_Type = 11  
92 -delete from WaterComponentsTypes where id_Type = 12  
93 -delete from WaterComponentsTypes where id_Type = 13  
94 -delete from WaterComponentsTypes where id_Type = 14  
95 -delete from WaterComponentsTypes where id_Type = 15  
96 -delete from WaterComponentsTypes where id_Type = 16  
97 -delete from WaterComponentsTypes where id_Type = 17  
98 -delete from WaterComponentsTypes where id_Type = 17  
99 -delete from WaterComponentsTypes where id_Type = 19  
100 -delete from WaterComponentsTypes where id_Type = 20  
101 -delete from WaterComponentsTypes where id_Type = 21  
102 -delete from WaterComponentsTypes where id_Type = 22  
103 -delete from WaterComponentsTypes where id_Type = 23  
104 -delete from WaterComponentsTypes where id_Type = 24  
105 -delete from WaterComponentsTypes where id_Type = 25  
106 -delete from WaterComponentsTypes where id_Type = 26  
107 -delete from WaterComponentsTypes where id_Type = 27  
108 -delete from WaterComponentsTypes where id_Type = 28  
109 -delete from WaterComponentsTypes where id_Type = 29  
110 -delete from WaterComponentsTypes where id_Type = 30  
111 -delete from WaterComponentsTypes where id_Type = 31  
112 -delete from WaterComponentsTypes where id_Type = 32  
113 -delete from WaterComponentsTypes where id_Type = 33  
114 -delete from WaterComponentsTypes where id_Type = 34  
115 -delete from WaterComponentsTypes where id_Type = 35  
116 -delete from WaterComponentsTypes where id_Type = 36  
117 -delete from WaterComponentsTypes where id_Type = 37  
118 -delete from WaterComponentsTypes where id_Type = 38  
119 -delete from WaterComponentsTypes where id_Type = 39  
120 -delete from WaterComponentsTypes where id_Type = 40  
121 -delete from WaterComponentsTypes where id_Type = 41  
122 -delete from WaterComponentsTypes where id_Type = 42  
123 -delete from WaterComponentsTypes where id_Type = 43  
124 -delete from WaterComponentsTypes where id_Type = 44  
125 -delete from WaterComponentsTypes where id_Type = 45  
126 -delete from WaterComponentsTypes where id_Type = 46  
127 -  
128 -/* insere parâmetros de todos subtipos */  
129 -  
130 -CREATE TABLE [dbo].[WaterComponentsSubTypes](  
131 - [id_Type] [int] NOT NULL,  
132 - [id_SubType] [int] NOT NULL,  
133 - [Description_] [varchar](50) NULL,  
134 - [Selection_] [bit] NOT NULL,  
135 - [Max_] [numeric](18, 4) NULL,  
136 - [Min_] [numeric](18, 4) NULL,  
137 - [DefaultValue] [nvarchar](50) NOT NULL,  
138 - [DataType] [int] NULL,  
139 - [EPAREF] [nvarchar](10) NULL  
140 -) ON [PRIMARY]  
141 -  
142 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')  
143 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)  
144 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')  
145 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')  
146 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
147 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
148 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
149 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')  
150 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
151 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')  
152 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')  
153 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
154 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')  
155 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')  
156 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')  
157 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
158 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
159 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
160 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
161 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
162 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
163 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')  
164 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')  
165 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')  
166 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
167 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
168 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
169 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
170 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
171 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
172 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
173 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
174 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
175 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
176 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
177 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
178 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
179 -  
180 -/* Modificado o formato do dado da coluna Value_ de WaterComponentsSelection */  
181 -  
182 -CREATE TABLE [dbo].[WaterComponentsSelections](  
183 - [id_Type] [int] NOT NULL,  
184 - [id_SubType] [int] NOT NULL,  
185 - [Option_] [varchar](25) NOT NULL,  
186 - [Value_] [nvarchar](50) NOT NULL,  
187 - [Description_] [varchar](30) NULL  
188 -) ON [PRIMARY]  
189 -  
190 -GO  
191 -  
192 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')  
193 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')  
194 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')  
195 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')  
196 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')  
197 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')  
198 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')  
199 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')  
200 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')  
201 -  
sql/20160210083900-scripts versao GeoSan 7.0.30.sql 0 → 100644
@@ -0,0 +1,102 @@ @@ -0,0 +1,102 @@
  1 +USE [ArturNogueira-B]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:40:47 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  23 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  24 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  25 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  26 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  27 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  59 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  60 +/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:40:47 ******/
  61 +SET ANSI_NULLS ON
  62 +GO
  63 +SET QUOTED_IDENTIFIER ON
  64 +GO
  65 +SET ANSI_PADDING ON
  66 +GO
  67 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  68 + [id_Type] [int] NOT NULL,
  69 + [id_SubType] [int] NOT NULL,
  70 + [Description_] [varchar](50) NULL,
  71 + [Selection_] [bit] NOT NULL,
  72 + [Max_] [numeric](18, 4) NULL,
  73 + [Min_] [numeric](18, 4) NULL,
  74 + [DefaultValue] [nvarchar](50) NOT NULL,
  75 + [DataType] [int] NULL,
  76 + [EPAREF] [nvarchar](10) NULL
  77 +) ON [PRIMARY]
  78 +GO
  79 +SET ANSI_PADDING OFF
  80 +GO
  81 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  82 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 129, NULL)
  83 +/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:40:47 ******/
  84 +SET ANSI_NULLS ON
  85 +GO
  86 +SET QUOTED_IDENTIFIER ON
  87 +GO
  88 +SET ANSI_PADDING ON
  89 +GO
  90 +CREATE TABLE [dbo].[WaterComponentsSelections](
  91 + [id_Type] [int] NOT NULL,
  92 + [id_SubType] [int] NOT NULL,
  93 + [Option_] [varchar](25) NOT NULL,
  94 + [Value_] [tinyint] NOT NULL,
  95 + [Description_] [varchar](30) NULL
  96 +) ON [PRIMARY]
  97 +GO
  98 +SET ANSI_PADDING OFF
  99 +GO
  100 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', 1, N'')
  101 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', 0, N'')
  102 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', 2, N'')
sql/20160210083900-scripts versão GeoSan 7.0.30.sql
@@ -1,102 +0,0 @@ @@ -1,102 +0,0 @@
1 -USE [ArturNogueira-B]  
2 -GO  
3 -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:40:47 ******/  
4 -SET ANSI_NULLS ON  
5 -GO  
6 -SET QUOTED_IDENTIFIER ON  
7 -GO  
8 -SET ANSI_PADDING ON  
9 -GO  
10 -CREATE TABLE [dbo].[WaterComponentsTypes](  
11 - [id_Type] [int] IDENTITY(1,1) NOT NULL,  
12 - [Description_] [varchar](25) NULL,  
13 - [Specification_] [varchar](100) NULL  
14 -) ON [PRIMARY]  
15 -GO  
16 -SET ANSI_PADDING OFF  
17 -GO  
18 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON  
19 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')  
20 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')  
21 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')  
22 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')  
23 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')  
24 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')  
25 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')  
26 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')  
27 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')  
28 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')  
29 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')  
30 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')  
31 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')  
32 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')  
33 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')  
34 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')  
35 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')  
36 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')  
37 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')  
38 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')  
39 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')  
40 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')  
41 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')  
42 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')  
43 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')  
44 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')  
45 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')  
46 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')  
47 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')  
48 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')  
49 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')  
50 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')  
51 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')  
52 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')  
53 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')  
54 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')  
55 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')  
56 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')  
57 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')  
58 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')  
59 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF  
60 -/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:40:47 ******/  
61 -SET ANSI_NULLS ON  
62 -GO  
63 -SET QUOTED_IDENTIFIER ON  
64 -GO  
65 -SET ANSI_PADDING ON  
66 -GO  
67 -CREATE TABLE [dbo].[WaterComponentsSubTypes](  
68 - [id_Type] [int] NOT NULL,  
69 - [id_SubType] [int] NOT NULL,  
70 - [Description_] [varchar](50) NULL,  
71 - [Selection_] [bit] NOT NULL,  
72 - [Max_] [numeric](18, 4) NULL,  
73 - [Min_] [numeric](18, 4) NULL,  
74 - [DefaultValue] [nvarchar](50) NOT NULL,  
75 - [DataType] [int] NULL,  
76 - [EPAREF] [nvarchar](10) NULL  
77 -) ON [PRIMARY]  
78 -GO  
79 -SET ANSI_PADDING OFF  
80 -GO  
81 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')  
82 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 129, NULL)  
83 -/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:40:47 ******/  
84 -SET ANSI_NULLS ON  
85 -GO  
86 -SET QUOTED_IDENTIFIER ON  
87 -GO  
88 -SET ANSI_PADDING ON  
89 -GO  
90 -CREATE TABLE [dbo].[WaterComponentsSelections](  
91 - [id_Type] [int] NOT NULL,  
92 - [id_SubType] [int] NOT NULL,  
93 - [Option_] [varchar](25) NOT NULL,  
94 - [Value_] [tinyint] NOT NULL,  
95 - [Description_] [varchar](30) NULL  
96 -) ON [PRIMARY]  
97 -GO  
98 -SET ANSI_PADDING OFF  
99 -GO  
100 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', 1, N'')  
101 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', 0, N'')  
102 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', 2, N'')  
sql/20160210084500-scripts completos dos metadados das componentes de agua.sql 0 → 100644
@@ -0,0 +1,147 @@ @@ -0,0 +1,147 @@
  1 +USE [ArturNogueira-B-1]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')
  23 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')
  24 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')
  25 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')
  26 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')
  27 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')
  28 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')
  29 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')
  30 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')
  31 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')
  32 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')
  33 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')
  34 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')
  35 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')
  36 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')
  37 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')
  38 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')
  39 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')
  40 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')
  41 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')
  42 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')
  43 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')
  44 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')
  45 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')
  46 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')
  47 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')
  48 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')
  49 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')
  50 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')
  51 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')
  52 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')
  53 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')
  54 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')
  55 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')
  56 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')
  57 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')
  58 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')
  59 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  60 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  61 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  62 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  63 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  64 +/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:45:01 ******/
  65 +SET ANSI_NULLS ON
  66 +GO
  67 +SET QUOTED_IDENTIFIER ON
  68 +GO
  69 +SET ANSI_PADDING ON
  70 +GO
  71 +CREATE TABLE [dbo].[WaterComponentsSubTypes](
  72 + [id_Type] [int] NOT NULL,
  73 + [id_SubType] [int] NOT NULL,
  74 + [Description_] [varchar](50) NULL,
  75 + [Selection_] [bit] NOT NULL,
  76 + [Max_] [numeric](18, 4) NULL,
  77 + [Min_] [numeric](18, 4) NULL,
  78 + [DefaultValue] [nvarchar](50) NOT NULL,
  79 + [DataType] [int] NULL,
  80 + [EPAREF] [nvarchar](10) NULL
  81 +) ON [PRIMARY]
  82 +GO
  83 +SET ANSI_PADDING OFF
  84 +GO
  85 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')
  86 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)
  87 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  88 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  89 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  90 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  91 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  92 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  93 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  94 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  95 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  96 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  97 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  98 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  99 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  100 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  101 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  102 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  103 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  104 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  105 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  106 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  107 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  108 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  109 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  110 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  111 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  112 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  113 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  114 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  115 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  116 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  117 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  118 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  119 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  120 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  121 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  122 +/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:45:01 ******/
  123 +SET ANSI_NULLS ON
  124 +GO
  125 +SET QUOTED_IDENTIFIER ON
  126 +GO
  127 +SET ANSI_PADDING ON
  128 +GO
  129 +CREATE TABLE [dbo].[WaterComponentsSelections](
  130 + [id_Type] [int] NOT NULL,
  131 + [id_SubType] [int] NOT NULL,
  132 + [Option_] [varchar](25) NOT NULL,
  133 + [Value_] [nvarchar](50) NOT NULL,
  134 + [Description_] [varchar](30) NULL
  135 +) ON [PRIMARY]
  136 +GO
  137 +SET ANSI_PADDING OFF
  138 +GO
  139 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')
  140 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')
  141 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')
  142 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  143 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  144 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  145 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  146 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  147 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
sql/20160210084500-scripts completos dos metadados das componentes de água.sql
@@ -1,147 +0,0 @@ @@ -1,147 +0,0 @@
1 -USE [ArturNogueira-B-1]  
2 -GO  
3 -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/  
4 -SET ANSI_NULLS ON  
5 -GO  
6 -SET QUOTED_IDENTIFIER ON  
7 -GO  
8 -SET ANSI_PADDING ON  
9 -GO  
10 -CREATE TABLE [dbo].[WaterComponentsTypes](  
11 - [id_Type] [int] IDENTITY(1,1) NOT NULL,  
12 - [Description_] [varchar](25) NULL,  
13 - [Specification_] [varchar](100) NULL  
14 -) ON [PRIMARY]  
15 -GO  
16 -SET ANSI_PADDING OFF  
17 -GO  
18 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON  
19 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (0, N'DESC.', N'JUNCTION')  
20 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (1, N'ADAPTADOR', N'JUNCTION')  
21 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (2, N'ATUADOR', N'JUNCTION')  
22 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (3, N'BOMBA', N'PUMP')  
23 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (4, N'BOOSTER', N'PUMP')  
24 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (5, N'CAP', N'JUNCTION')  
25 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (6, N'CAPTAÇÃO AGUA BRUTA', N'JUNCTION')  
26 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (7, N'CRUZETA', N'JUNCTION')  
27 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (8, N'CURVA 11-15', N'JUNCTION')  
28 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (9, N'CURVA 22-30', N'JUNCTION')  
29 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (10, N'CURVA 45', N'JUNCTION')  
30 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (11, N'CURVA 90', N'JUNCTION')  
31 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (12, N'DESCARGA', N'JUNCTION')  
32 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (13, N'ELEVATORIA DE AGUA', N'JUNCTION')  
33 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (14, N'FILTRO', N'JUNCTION')  
34 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (15, N'HIDRANTE', N'JUNCTION')  
35 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (16, N'HIDRÔMETRO', N'JUNCTION')  
36 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (17, N'JUNÇÃO', N'JUNCTION')  
37 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (18, N'JUNTA DE ADAPTAÇÃO', N'JUNCTION')  
38 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (19, N'LUVA', N'JUNCTION')  
39 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (20, N'MACRO MEDIDOR', N'JUNCTION')  
40 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (21, N'MEDIDOR DE NÍVEL', N'JUNCTION')  
41 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (22, N'MEDIDOR PRESSÃO', N'JUNCTION')  
42 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (23, N'MEDIDOR VAZÃO', N'JUNCTION')  
43 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (24, N'NÃO IDENTIFICADO', N'JUNCTION')  
44 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (25, N'RNF-Poço Profundo', N'RNF')  
45 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (26, N'REDUÇÃO', N'JUNCTION')  
46 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (27, N'REGISTRO', N'REGISTER')  
47 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (28, N'RNV-Reserv Nível Variável', N'RNV')  
48 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (29, N'TE', N'JUNCTION')  
49 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (30, N'VALVULA RETENÇÃO', N'JUNCTION')  
50 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (31, N'VENTOSA', N'JUNCTION')  
51 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (32, N'PRV-Válvula Red Pres', N'VALVE')  
52 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (35, N'REG. FIXO', N'JUNCTION')  
53 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (36, N'RNF-Reserv Nível Fixo', N'RNF')  
54 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (38, N'PSV-Válvula Sus Pres', N'VALVE')  
55 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (39, N'PBV-Válvula Perda Carga F', N'VALVE')  
56 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (40, N'FCV-Válvula Reg Vazão', N'VALVE')  
57 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (41, N'TCV-Válvula Contr Perda C', N'VALVE')  
58 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (42, N'GPV-Válvula Genérica', N'REGISTER')  
59 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')  
60 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')  
61 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')  
62 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')  
63 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF  
64 -/****** Object: Table [dbo].[WaterComponentsSubTypes] Script Date: 02/10/2016 08:45:01 ******/  
65 -SET ANSI_NULLS ON  
66 -GO  
67 -SET QUOTED_IDENTIFIER ON  
68 -GO  
69 -SET ANSI_PADDING ON  
70 -GO  
71 -CREATE TABLE [dbo].[WaterComponentsSubTypes](  
72 - [id_Type] [int] NOT NULL,  
73 - [id_SubType] [int] NOT NULL,  
74 - [Description_] [varchar](50) NULL,  
75 - [Selection_] [bit] NOT NULL,  
76 - [Max_] [numeric](18, 4) NULL,  
77 - [Min_] [numeric](18, 4) NULL,  
78 - [DefaultValue] [nvarchar](50) NOT NULL,  
79 - [DataType] [int] NULL,  
80 - [EPAREF] [nvarchar](10) NULL  
81 -) ON [PRIMARY]  
82 -GO  
83 -SET ANSI_PADDING OFF  
84 -GO  
85 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 1, N'SITUAÇÃO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'')  
86 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (27, 2, N'NÚMERO DO REGISTRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, NULL)  
87 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')  
88 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')  
89 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
90 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
91 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
92 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')  
93 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
94 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')  
95 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')  
96 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
97 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')  
98 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')  
99 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')  
100 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
101 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
102 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
103 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
104 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
105 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
106 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')  
107 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')  
108 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')  
109 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
110 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
111 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
112 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
113 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
114 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
115 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
116 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
117 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
118 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
119 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
120 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
121 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
122 -/****** Object: Table [dbo].[WaterComponentsSelections] Script Date: 02/10/2016 08:45:01 ******/  
123 -SET ANSI_NULLS ON  
124 -GO  
125 -SET QUOTED_IDENTIFIER ON  
126 -GO  
127 -SET ANSI_PADDING ON  
128 -GO  
129 -CREATE TABLE [dbo].[WaterComponentsSelections](  
130 - [id_Type] [int] NOT NULL,  
131 - [id_SubType] [int] NOT NULL,  
132 - [Option_] [varchar](25) NOT NULL,  
133 - [Value_] [nvarchar](50) NOT NULL,  
134 - [Description_] [varchar](30) NULL  
135 -) ON [PRIMARY]  
136 -GO  
137 -SET ANSI_PADDING OFF  
138 -GO  
139 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'ABERTO', N'1', N'')  
140 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'DESCONHECIDA', N'0', N'')  
141 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (27, 1, N'FECHADO', N'2', N'')  
142 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')  
143 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')  
144 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')  
145 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')  
146 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')  
147 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')  
sql/20160210084600-scripts para atualizar para versao 7.0.44.sql 0 → 100644
@@ -0,0 +1,69 @@ @@ -0,0 +1,69 @@
  1 +USE [ArturNogueira-B-1]
  2 +GO
  3 +/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/
  4 +SET ANSI_NULLS ON
  5 +GO
  6 +SET QUOTED_IDENTIFIER ON
  7 +GO
  8 +SET ANSI_PADDING ON
  9 +GO
  10 +CREATE TABLE [dbo].[WaterComponentsTypes](
  11 + [id_Type] [int] IDENTITY(1,1) NOT NULL,
  12 + [Description_] [varchar](25) NULL,
  13 + [Specification_] [varchar](100) NULL
  14 +) ON [PRIMARY]
  15 +GO
  16 +SET ANSI_PADDING OFF
  17 +GO
  18 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON /* rodar esta linha antes de realizar as inserções */
  19 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')
  20 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')
  21 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')
  22 +INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')
  23 +SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF
  24 +
  25 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')
  26 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')
  27 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  28 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  29 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  30 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')
  31 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  32 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')
  33 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')
  34 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  35 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')
  36 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')
  37 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')
  38 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  39 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  40 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  41 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  42 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  43 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')
  44 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')
  45 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')
  46 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')
  47 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')
  48 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  49 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  50 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  51 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')
  52 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')
  53 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  54 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  55 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  56 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')
  57 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')
  58 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')
  59 +INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')
  60 +
  61 +/* Selecione no SQLServer Management Studio: Tools - Options - Designer e então retire a seleção de Prevent saving changes that require the table re-creation */
  62 +ALTER TABLE [dbo].[WaterComponentsSelections] ALTER COLUMN [Value_] [nvarchar](50)
  63 +
  64 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')
  65 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')
  66 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')
  67 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')
  68 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')
  69 +INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')
sql/20160210084600-scripts para atualizar para versão 7.0.44.sql
@@ -1,69 +0,0 @@ @@ -1,69 +0,0 @@
1 -USE [ArturNogueira-B-1]  
2 -GO  
3 -/****** Object: Table [dbo].[WaterComponentsTypes] Script Date: 02/10/2016 08:45:01 ******/  
4 -SET ANSI_NULLS ON  
5 -GO  
6 -SET QUOTED_IDENTIFIER ON  
7 -GO  
8 -SET ANSI_PADDING ON  
9 -GO  
10 -CREATE TABLE [dbo].[WaterComponentsTypes](  
11 - [id_Type] [int] IDENTITY(1,1) NOT NULL,  
12 - [Description_] [varchar](25) NULL,  
13 - [Specification_] [varchar](100) NULL  
14 -) ON [PRIMARY]  
15 -GO  
16 -SET ANSI_PADDING OFF  
17 -GO  
18 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] ON /* rodar esta linha antes de realizar as inserções */  
19 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (43, N'VÁLVULA', N'VALVE')  
20 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (44, N'BOMBA POT', N'PUMP')  
21 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (45, N'BOMBA CARGA', N'PUMP')  
22 -INSERT [dbo].[WaterComponentsTypes] ([id_Type], [Description_], [Specification_]) VALUES (46, N'BOMBA CURVA', N'PUMP')  
23 -SET IDENTITY_INSERT [dbo].[WaterComponentsTypes] OFF  
24 -  
25 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 1, N'ALT INICIAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NINICIAL')  
26 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 2, N'ALT MIN', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMINIMO')  
27 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
28 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 2, N'CARGA (ALT)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
29 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 3, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
30 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 4, N'RENDIMENTO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'RENDIM')  
31 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 5, N'CURVA DA BOMBA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
32 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 6, N'CURVA DE REND', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURREND')  
33 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 3, N'ALT MAX', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'NMAXIMO')  
34 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 4, N'DIÂMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
35 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 5, N'CURVA DE VOLUME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'VOLCURVE')  
36 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 1, N'PARAM CONTROLE', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PARCONT')  
37 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 1, N'NÍVEL ÁGUA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'HEAD')  
38 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 2, N'PADRÃO DE NÍVEL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
39 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (32, 2, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
40 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (36, 3, N'NOME', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
41 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (3, 7, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
42 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (28, 6, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
43 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 1, N'DIAMETRO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'DIAMETER')  
44 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 2, N'TIPO', 1, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'TYPE')  
45 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 3, N'PARAM CONTR', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'SETTING')  
46 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (43, 4, N'COEF PERDA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'MINORLOSS')  
47 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 1, N'POTÊNCIA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'POWER')  
48 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
49 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
50 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (44, 4, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
51 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 1, N'ALTURA (CARGA)', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'CARGA')  
52 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 2, N'VAZÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'VAZAO')  
53 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 3, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
54 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 4, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
55 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (45, 5, N'DESCRIÇÃO', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
56 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 1, N'CURVA', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'CURBOMBA')  
57 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 2, N'REG VELOC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 5, N'SPEED')  
58 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 3, N'PADRÃO TEMPORAL', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 2, N'PATTERN')  
59 -INSERT [dbo].[WaterComponentsSubTypes] ([id_Type], [id_SubType], [Description_], [Selection_], [Max_], [Min_], [DefaultValue], [DataType], [EPAREF]) VALUES (46, 4, N'DESC', 0, CAST(0.0000 AS Numeric(18, 4)), CAST(0.0000 AS Numeric(18, 4)), N'0', 202, N'DESC')  
60 -  
61 -/* Selecione no SQLServer Management Studio: Tools - Options - Designer e então retire a seleção de Prevent saving changes that require the table re-creation */  
62 -ALTER TABLE [dbo].[WaterComponentsSelections] ALTER COLUMN [Value_] [nvarchar](50)  
63 -  
64 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PRV-RED PRESSÃO', N'1', N'Válvula redutora de pressão')  
65 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PSV-SUST PRESSÃO', N'2', N'Válvula Sustent. de Pressão')  
66 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'PBV-PERDA CARGA', N'3', N'Válvula de perda de carga fixa')  
67 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'FCV-REG VAZÃO', N'4', N'Válvula reguladora de vazão')  
68 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'TCV-CONT PERDA CARGA', N'5', N'Válvula contr de perda carga')  
69 -INSERT [dbo].[WaterComponentsSelections] ([id_Type], [id_SubType], [Option_], [Value_], [Description_]) VALUES (43, 2, N'GPV-GENÉRICA', N'6', N'Válvula genérica')  
trunk/Forms/frm1TePrinter - Copia.frm 0 → 100644
@@ -0,0 +1,477 @@ @@ -0,0 +1,477 @@
  1 +VERSION 5.00
  2 +Object = "{F141AAE7-BD4C-4793-88DB-10FE8CBA518C}#1.0#0"; "TeComPrinter.dll"
  3 +Object = "{9AB389E7-EAED-4DBF-941D-EB86ED1F9A76}#1.0#0"; "TeComConnection.dll"
  4 +Object = "{EE78E37B-39BE-42FA-80B7-E525529739F7}#1.0#0"; "TeComViewDatabase.dll"
  5 +Object = "{F9043C88-F6F2-101A-A3C9-08002B2F49FB}#1.2#0"; "COMDLG32.OCX"
  6 +Object = "{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0"; "MSCOMCTL.OCX"
  7 +Begin VB.Form frmTePrinter
  8 + Caption = "Módulo de Impressão"
  9 + ClientHeight = 10620
  10 + ClientLeft = 60
  11 + ClientTop = 750
  12 + ClientWidth = 9960
  13 + LinkTopic = "Form1"
  14 + ScaleHeight = 10620
  15 + ScaleWidth = 9960
  16 + StartUpPosition = 1 'CenterOwner
  17 + Begin TeComPrinterLibCtl.TePrinter TePrinter1
  18 + Height = 9375
  19 + Left = 120
  20 + Begin VB.Menu mnArquivo
  21 + Caption = "Arquivo"
  22 + Begin VB.Menu mnConfPagina
  23 + Caption = "Configurar Página"
  24 + End
  25 + Begin VB.Menu mnImprimir
  26 + Caption = "Imprimir"
  27 + End
  28 + Begin VB.Menu mnSep1
  29 + Caption = "-"
  30 + End
  31 + Begin VB.Menu mnFechar
  32 + Caption = "Fechar"
  33 + End
  34 + End
  35 + Begin VB.Menu mnEditar
  36 + Caption = "Editar"
  37 + Begin VB.Menu mnFonte
  38 + Caption = "Fonte"
  39 + Begin VB.Menu mnTamanho
  40 + Caption = "Tamanho"
  41 + Begin VB.Menu mn8
  42 + Caption = "8"
  43 + End
  44 + Begin VB.Menu mn12
  45 + Caption = "12"
  46 + End
  47 + Begin VB.Menu mn16
  48 + Caption = "16"
  49 + End
  50 + Begin VB.Menu mn32
  51 + Caption = "32"
  52 + End
  53 + End
  54 + Begin VB.Menu mnTipo
  55 + Caption = "Tipo"
  56 + Begin VB.Menu mnArial
  57 + Caption = "Arial"
  58 + End
  59 + Begin VB.Menu mnCourrier
  60 + Caption = "Arial Negrito"
  61 + End
  62 + End
  63 + End
  64 + End
  65 + Begin VB.Menu mnInserir
  66 + Caption = "Inserir"
  67 + Begin VB.Menu mnMapa
  68 + Caption = "Mapa"
  69 + End
  70 + Begin VB.Menu mnImagem
  71 + Caption = "Imagem"
  72 + End
  73 + Begin VB.Menu mnTexto
  74 + Caption = "Texto"
  75 + End
  76 + Begin VB.Menu mnLinha
  77 + Caption = "Linha"
  78 + End
  79 + Begin VB.Menu mnRetangulo
  80 + Caption = "Retangulo"
  81 + End
  82 + Begin VB.Menu mnElipse
  83 + Caption = "Elipse"
  84 + End
  85 + Begin VB.Menu mnBarraEscala
  86 + Caption = "Barra de Escala"
  87 + End
  88 + End
  89 + Begin VB.Menu mnAcaoMapa
  90 + Caption = "Mapa"
  91 + Begin VB.Menu mnMover
  92 + Caption = "Mover"
  93 + End
  94 + Begin VB.Menu mnAproximar
  95 + Caption = "Aproximar"
  96 + End
  97 + Begin VB.Menu mnAfastar
  98 + Caption = "Afastar"
  99 + End
  100 + Begin VB.Menu mnEscala
  101 + Caption = "Definir Escala"
  102 + End
  103 + End
  104 +End
  105 +Attribute VB_Name = "frmTePrinter"
  106 +Attribute VB_GlobalNameSpace = False
  107 +Attribute VB_Creatable = False
  108 +Attribute VB_PredeclaredId = True
  109 +Attribute VB_Exposed = False
  110 +Dim ObjName As String
  111 +Dim contador As Integer
  112 +Dim mPROVEDOR As String
  113 +Dim mSERVIDOR As String
  114 +Dim mPORTA As String
  115 +Dim mBANCO As String
  116 +Dim mUSUARIO As String
  117 +Dim Senha As String
  118 +Dim decriptada As String
  119 +Dim username As String
  120 +
  121 +
  122 +
  123 +Private Sub mnEscala_Click()
  124 +On Error GoTo saida
  125 + Dim Scala As Double
  126 +
  127 +
  128 + If CStr(ObjName) <> "" Then
  129 +
  130 + Scala = InputBox("", "Informe a escala do mapa")
  131 +
  132 + If Scala > 0 Then
  133 + TePrinter1.setObjectPropertyValueByName ObjName, "MapScale_Property", CDbl(Scala)
  134 + TePrinter1.execute
  135 +
  136 + End If
  137 + Else
  138 +
  139 + MsgBox "Selecione o mapa antes de definir a escala.", vbInformation, ""
  140 +
  141 + End If
  142 +saida:
  143 +
  144 +End Sub
  145 +
  146 +Private Function MudaFonte(Tam As Double)
  147 +On Error GoTo saida
  148 +Dim tamTexto As String
  149 +
  150 + 'retorna todos os nomes de propriedades
  151 + 'tamTexto = TePrinter1.getLayoutObjectPropertyName(ObjName, 5)
  152 +
  153 + TePrinter1.setObjectPropertyValue ObjName, 6, Tam
  154 + TePrinter1.execute
  155 +
  156 +
  157 +saida:
  158 +
  159 +End Function
  160 +
  161 +Private Function MudaTipoFonte(tipo As String)
  162 +On Error GoTo saida
  163 +
  164 + 'ObjName = Me.TePrinter1.getLayoutObjectPropertyValue("Text_2", 7) 'fonte
  165 +
  166 + TePrinter1.setObjectPropertyValue ObjName, 7, tipo
  167 + TePrinter1.execute
  168 +
  169 +saida:
  170 +End Function
  171 +
  172 +Public Function id_objeto()
  173 +Dim qtd As Integer
  174 +
  175 + 'VERIFICA SE ALGO SELECIONADO
  176 + qtd = Me.TePrinter1.getLayoutSelectObjectCount
  177 + If qtd > 0 Then
  178 +
  179 + 'PASSA PARA O ObjName O NOME DO OBJETO SELECIONADO
  180 + ObjName = Me.TePrinter1.getLayoutSelectObjectName(0)
  181 +
  182 + End If
  183 +
  184 +
  185 +
  186 +End Function
  187 +
  188 +
  189 +Private Sub cmdSetScale_Click()
  190 + Dim Texto As String
  191 + Texto = InputBox("Informe o texto:")
  192 +
  193 + If Trim(Texto) <> "" Then
  194 + TePrinter1.addText Texto
  195 + End If
  196 +
  197 + TePrinter1.setObjectPropertyValueByName strObjSelecionado, "MapScale_Property", CDbl(txtScala.Text)
  198 + TePrinter1.execute
  199 +End Sub
  200 +
  201 +
  202 +Private Sub Form_Load()
  203 +
  204 + TePrinter1.Provider = frmCanvas.TipoConexao
  205 +
  206 +If (frmCanvas.TipoConexao = 4) Then
  207 +
  208 +If (contador <> 10) Then
  209 +
  210 +mSERVIDOR = ReadINI("CONEXAO", "SERVIDOR", App.path & "\CONTROLES\GEOSAN.ini")
  211 +mPORTA = ReadINI("CONEXAO", "PORTA", App.path & "\CONTROLES\GEOSAN.ini")
  212 +mBANCO = ReadINI("CONEXAO", "BANCO", App.path & "\CONTROLES\GEOSAN.ini")
  213 +mUSUARIO = ReadINI("CONEXAO", "USUARIO", App.path & "\CONTROLES\GEOSAN.ini")
  214 +Senha = ReadINI("CONEXAO", "SENHA", App.path & "\CONTROLES\GEOSAN.ini")
  215 +username = ReadINI("CONEXAO", "USER", App.path & "\CONTROLES\GEOSAN.ini")
  216 +frmCanvas.FunDecripta (Senha)
  217 +decriptada = frmCanvas.Senha
  218 +
  219 +TeAcXConnection1.Open mUSUARIO, decriptada, mBANCO, mSERVIDOR, mPORTA
  220 +contador = 10
  221 +
  222 +Else
  223 +
  224 +TePrinter1.Provider = frmCanvas.TipoConexao
  225 +'TePrinter1.connection = TeAcXConnection1.objectConnection_
  226 +
  227 +End If
  228 +
  229 +Else
  230 +TePrinter1.Provider = frmCanvas.TipoConexao
  231 +TePrinter1.connection = Conn
  232 +
  233 +End If
  234 +
  235 +TePrinter1.execute
  236 +
  237 +End Sub
  238 +
  239 +Private Sub Form_Resize()
  240 +On Error GoTo Trata_Erro
  241 +
  242 +TePrinter1.Width = 9960
  243 +TePrinter1.Height = Me.Height - 1250 '- tbMain.Height
  244 +
  245 +Trata_Erro:
  246 +
  247 +If Err.Number = 0 Or Err.Number = 20 Then
  248 + Resume Next
  249 +Else
  250 + Exit Sub
  251 +End If
  252 +
  253 +End Sub
  254 +
  255 +Private Sub mn8_Click()
  256 + MudaFonte 8
  257 +End Sub
  258 +
  259 +Private Sub mn12_Click()
  260 +
  261 +
  262 + TePrinter1.setObjectPropertyValue ObjName, 6, 12 'CLng(tamanho)
  263 + TePrinter1.execute
  264 +
  265 +End Sub
  266 +
  267 +Private Sub mn16_Click()
  268 + MudaFonte 16
  269 +End Sub
  270 +
  271 +Private Sub mn32_Click()
  272 + MudaFonte 32
  273 +End Sub
  274 +
  275 +
  276 +
  277 +Private Sub mnAfastar_Click()
  278 + TePrinter1.setMapMode zoomOut
  279 +End Sub
  280 +
  281 +Private Sub mnAproximar_Click()
  282 + TePrinter1.setMapMode zoomIn
  283 +End Sub
  284 +
  285 +Private Sub mnArial_Click()
  286 + MudaTipoFonte "Arial"
  287 +End Sub
  288 +
  289 +Private Sub mnCourrier_Click()
  290 + MudaTipoFonte "Arial Black"
  291 +End Sub
  292 +
  293 +Private Sub mnLucConsole_Click()
  294 + MudaTipoFonte "Lucida Console"
  295 +End Sub
  296 +
  297 +Private Sub mnConfPagina_Click()
  298 + If TePrinter1.orientation = portrait Then
  299 + frmPageSetup.setOrientation True
  300 + Else
  301 + frmPageSetup.setOrientation False
  302 + End If
  303 +
  304 + frmPageSetup.setPageSize TePrinter1.PaperSize
  305 +
  306 + frmPageSetup.Show 1, Me
  307 + If frmPageSetup.getOK = True Then
  308 + If frmPageSetup.getOrientation = True Then
  309 + TePrinter1.orientation = portrait
  310 + Else
  311 + TePrinter1.orientation = landscape
  312 + End If
  313 + TePrinter1.PaperSize = frmPageSetup.getPageSize
  314 +
  315 + TePrinter1.execute
  316 + End If
  317 +End Sub
  318 +
  319 +
  320 +
  321 +
  322 +
  323 +
  324 +
  325 +Private Sub mnImagem_Click()
  326 + cmmOpen.ShowOpen
  327 + TePrinter1.addImage cmmOpen.FileName
  328 +End Sub
  329 +
  330 +Private Sub mnImprimir_Click()
  331 +
  332 + TePrinter1.printExecute ("Teste")
  333 +
  334 +End Sub
  335 +
  336 +Private Sub mnLinha_Click()
  337 +
  338 + TePrinter1.addLine
  339 +
  340 +End Sub
  341 +
  342 +
  343 +
  344 +Private Sub mnMover_Click()
  345 + TePrinter1.setMapMode pan
  346 +End Sub
  347 +
  348 +Private Sub mnBarraEscala_Click()
  349 + TePrinter1.addScale
  350 +End Sub
  351 +
  352 +
  353 +
  354 +
  355 +Private Sub mnMapa_Click()
  356 +
  357 + 'COLETA AS VARIÁVEIS GLOBAIS PARA O MÓDULO DE IMPRESSÃO PASSADAS NO END PLOT VIEW
  358 + 'CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  359 +
  360 + 'ADICIONA O MAPA QUE ESTAVA NA TELA DO GEOSAN
  361 + 'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  362 +
  363 +If (frmCanvas.TipoConexao = 4) Then
  364 +
  365 +'TePrinter1.provider = TeComPrinterLib.CONNECTION_TYPE.PostgreSQL;
  366 +TePrinter1.addDatabase
  367 +TePrinter1.execute
  368 +'TePrinter1.Open ("nexussql.gpl")
  369 +'TePrinter1.execute
  370 +
  371 +
  372 +
  373 +TePrinter1.setObjectPropertyValueByName "Database_1", "left_Property", "15.0"
  374 +TePrinter1.execute
  375 +TePrinter1.setObjectPropertyValueByName "Database_1", "top_Property", "20.0"
  376 +TePrinter1.execute
  377 +TePrinter1.setObjectPropertyValueByName "Database_1", "width_Property", "11.0"
  378 +TePrinter1.execute
  379 +TePrinter1.setObjectPropertyValueByName "Database_1", "height_Property", "11.0"
  380 +TePrinter1.execute
  381 +TePrinter1.setObjectPropertyValueByName "Database_1", "angle_Property", "0.0"
  382 +TePrinter1.execute
  383 +
  384 +TePrinter1.setObjectPropertyValueByName "Database_1", "username_Property", "postgres"
  385 +TePrinter1.execute
  386 +TePrinter1.setObjectPropertyValueByName "Database_1", "password_Property", "gustavo"
  387 +TePrinter1.execute
  388 +TePrinter1.setObjectPropertyValueByName "Database_1", "host_Property", "localhost"
  389 +TePrinter1.execute
  390 +TePrinter1.setObjectPropertyValueByName "Database_1", "databasename_Property", "teste"
  391 +TePrinter1.execute
  392 +TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
  393 +TePrinter1.execute
  394 +TePrinter1.setObjectPropertyValueByName "Database_1", "databasetype_Property", "2.0"
  395 +TePrinter1.execute
  396 +
  397 +
  398 +
  399 +TePrinter1.setObjectPropertyValueByName "Map_3", "viewname_Property", "Administrador"
  400 +TePrinter1.execute
  401 +TePrinter1.setObjectPropertyValueByName "Map_3", "viewuser_Property", "Administrador"
  402 +TePrinter1.execute
  403 +TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
  404 +TePrinter1.execute
  405 +
  406 +TePrinter1.setObjectPropertyValueByName "Map_3", "left_Property", "15.0"
  407 +TePrinter1.execute
  408 +TePrinter1.setObjectPropertyValueByName "Map_3", "top_Property", "44.0"
  409 +TePrinter1.execute
  410 +TePrinter1.setObjectPropertyValueByName "Map_3", "width_Property", "300.0"
  411 +TePrinter1.execute
  412 +TePrinter1.setObjectPropertyValueByName "Map_3", "height_Property", "200.0"
  413 +TePrinter1.execute
  414 +TePrinter1.setObjectPropertyValueByName "Map_3", "angle_Property", "0.0"
  415 +TePrinter1.execute
  416 +
  417 +TePrinter1.setObjectPropertyValueByName "Map_3", "mapscale_Property", "2200000"
  418 +TePrinter1.execute
  419 +
  420 +TePrinter1.setObjectPropertyValueByName "Map_3", "fixedscale_Property", "False"
  421 +TePrinter1.execute
  422 +
  423 +
  424 +
  425 +
  426 +'TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"
  427 +'TePrinter1.execute
  428 +
  429 +
  430 +'TePrinter1.addDatabase
  431 +
  432 +'TePrinter1.execute
  433 +'TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"
  434 +
  435 +
  436 +
  437 +
  438 +End If
  439 +
  440 +'update te_layer set lower_x = 715603;
  441 +'update te_layer set lower_y = 7702100;
  442 +'update te_layer set upper_x = 722075;
  443 +'update te_layer set upper_y = 7711330;
  444 +TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  445 +'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_
  446 +
  447 +End Sub
  448 +
  449 +Private Sub mnRetangulo_Click()
  450 + TePrinter1.addRectangle
  451 +End Sub
  452 +
  453 +Private Sub mnElipse_Click()
  454 + TePrinter1.addEllipse
  455 +End Sub
  456 +
  457 +Private Sub mnTexto_Click()
  458 + Dim Texto As String
  459 + Texto = InputBox("Informe o texto:")
  460 +
  461 + If Trim(Texto) <> "" Then
  462 + TePrinter1.addText Texto
  463 + End If
  464 +
  465 +End Sub
  466 +
  467 +
  468 +Private Sub TePrinter1_endProcess(ByVal partial As Boolean)
  469 +
  470 + DoEvents
  471 + If (partial = False) Then
  472 + 'mnProperties_Click
  473 + id_objeto
  474 + End If
  475 +End Sub
  476 +
  477 +
trunk/Forms/frm1TePrinter - Cópia.frm
@@ -1,477 +0,0 @@ @@ -1,477 +0,0 @@
1 -VERSION 5.00  
2 -Object = "{F141AAE7-BD4C-4793-88DB-10FE8CBA518C}#1.0#0"; "TeComPrinter.dll"  
3 -Object = "{9AB389E7-EAED-4DBF-941D-EB86ED1F9A76}#1.0#0"; "TeComConnection.dll"  
4 -Object = "{EE78E37B-39BE-42FA-80B7-E525529739F7}#1.0#0"; "TeComViewDatabase.dll"  
5 -Object = "{F9043C88-F6F2-101A-A3C9-08002B2F49FB}#1.2#0"; "COMDLG32.OCX"  
6 -Object = "{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0"; "MSCOMCTL.OCX"  
7 -Begin VB.Form frmTePrinter  
8 - Caption = "Módulo de Impressão"  
9 - ClientHeight = 10620  
10 - ClientLeft = 60  
11 - ClientTop = 750  
12 - ClientWidth = 9960  
13 - LinkTopic = "Form1"  
14 - ScaleHeight = 10620  
15 - ScaleWidth = 9960  
16 - StartUpPosition = 1 'CenterOwner  
17 - Begin TeComPrinterLibCtl.TePrinter TePrinter1  
18 - Height = 9375  
19 - Left = 120  
20 - Begin VB.Menu mnArquivo  
21 - Caption = "Arquivo"  
22 - Begin VB.Menu mnConfPagina  
23 - Caption = "Configurar Página"  
24 - End  
25 - Begin VB.Menu mnImprimir  
26 - Caption = "Imprimir"  
27 - End  
28 - Begin VB.Menu mnSep1  
29 - Caption = "-"  
30 - End  
31 - Begin VB.Menu mnFechar  
32 - Caption = "Fechar"  
33 - End  
34 - End  
35 - Begin VB.Menu mnEditar  
36 - Caption = "Editar"  
37 - Begin VB.Menu mnFonte  
38 - Caption = "Fonte"  
39 - Begin VB.Menu mnTamanho  
40 - Caption = "Tamanho"  
41 - Begin VB.Menu mn8  
42 - Caption = "8"  
43 - End  
44 - Begin VB.Menu mn12  
45 - Caption = "12"  
46 - End  
47 - Begin VB.Menu mn16  
48 - Caption = "16"  
49 - End  
50 - Begin VB.Menu mn32  
51 - Caption = "32"  
52 - End  
53 - End  
54 - Begin VB.Menu mnTipo  
55 - Caption = "Tipo"  
56 - Begin VB.Menu mnArial  
57 - Caption = "Arial"  
58 - End  
59 - Begin VB.Menu mnCourrier  
60 - Caption = "Arial Negrito"  
61 - End  
62 - End  
63 - End  
64 - End  
65 - Begin VB.Menu mnInserir  
66 - Caption = "Inserir"  
67 - Begin VB.Menu mnMapa  
68 - Caption = "Mapa"  
69 - End  
70 - Begin VB.Menu mnImagem  
71 - Caption = "Imagem"  
72 - End  
73 - Begin VB.Menu mnTexto  
74 - Caption = "Texto"  
75 - End  
76 - Begin VB.Menu mnLinha  
77 - Caption = "Linha"  
78 - End  
79 - Begin VB.Menu mnRetangulo  
80 - Caption = "Retangulo"  
81 - End  
82 - Begin VB.Menu mnElipse  
83 - Caption = "Elipse"  
84 - End  
85 - Begin VB.Menu mnBarraEscala  
86 - Caption = "Barra de Escala"  
87 - End  
88 - End  
89 - Begin VB.Menu mnAcaoMapa  
90 - Caption = "Mapa"  
91 - Begin VB.Menu mnMover  
92 - Caption = "Mover"  
93 - End  
94 - Begin VB.Menu mnAproximar  
95 - Caption = "Aproximar"  
96 - End  
97 - Begin VB.Menu mnAfastar  
98 - Caption = "Afastar"  
99 - End  
100 - Begin VB.Menu mnEscala  
101 - Caption = "Definir Escala"  
102 - End  
103 - End  
104 -End  
105 -Attribute VB_Name = "frmTePrinter"  
106 -Attribute VB_GlobalNameSpace = False  
107 -Attribute VB_Creatable = False  
108 -Attribute VB_PredeclaredId = True  
109 -Attribute VB_Exposed = False  
110 -Dim ObjName As String  
111 -Dim contador As Integer  
112 -Dim mPROVEDOR As String  
113 -Dim mSERVIDOR As String  
114 -Dim mPORTA As String  
115 -Dim mBANCO As String  
116 -Dim mUSUARIO As String  
117 -Dim Senha As String  
118 -Dim decriptada As String  
119 -Dim username As String  
120 -  
121 -  
122 -  
123 -Private Sub mnEscala_Click()  
124 -On Error GoTo saida  
125 - Dim Scala As Double  
126 -  
127 -  
128 - If CStr(ObjName) <> "" Then  
129 -  
130 - Scala = InputBox("", "Informe a escala do mapa")  
131 -  
132 - If Scala > 0 Then  
133 - TePrinter1.setObjectPropertyValueByName ObjName, "MapScale_Property", CDbl(Scala)  
134 - TePrinter1.execute  
135 -  
136 - End If  
137 - Else  
138 -  
139 - MsgBox "Selecione o mapa antes de definir a escala.", vbInformation, ""  
140 -  
141 - End If  
142 -saida:  
143 -  
144 -End Sub  
145 -  
146 -Private Function MudaFonte(Tam As Double)  
147 -On Error GoTo saida  
148 -Dim tamTexto As String  
149 -  
150 - 'retorna todos os nomes de propriedades  
151 - 'tamTexto = TePrinter1.getLayoutObjectPropertyName(ObjName, 5)  
152 -  
153 - TePrinter1.setObjectPropertyValue ObjName, 6, Tam  
154 - TePrinter1.execute  
155 -  
156 -  
157 -saida:  
158 -  
159 -End Function  
160 -  
161 -Private Function MudaTipoFonte(tipo As String)  
162 -On Error GoTo saida  
163 -  
164 - 'ObjName = Me.TePrinter1.getLayoutObjectPropertyValue("Text_2", 7) 'fonte  
165 -  
166 - TePrinter1.setObjectPropertyValue ObjName, 7, tipo  
167 - TePrinter1.execute  
168 -  
169 -saida:  
170 -End Function  
171 -  
172 -Public Function id_objeto()  
173 -Dim qtd As Integer  
174 -  
175 - 'VERIFICA SE ALGO SELECIONADO  
176 - qtd = Me.TePrinter1.getLayoutSelectObjectCount  
177 - If qtd > 0 Then  
178 -  
179 - 'PASSA PARA O ObjName O NOME DO OBJETO SELECIONADO  
180 - ObjName = Me.TePrinter1.getLayoutSelectObjectName(0)  
181 -  
182 - End If  
183 -  
184 -  
185 -  
186 -End Function  
187 -  
188 -  
189 -Private Sub cmdSetScale_Click()  
190 - Dim Texto As String  
191 - Texto = InputBox("Informe o texto:")  
192 -  
193 - If Trim(Texto) <> "" Then  
194 - TePrinter1.addText Texto  
195 - End If  
196 -  
197 - TePrinter1.setObjectPropertyValueByName strObjSelecionado, "MapScale_Property", CDbl(txtScala.Text)  
198 - TePrinter1.execute  
199 -End Sub  
200 -  
201 -  
202 -Private Sub Form_Load()  
203 -  
204 - TePrinter1.Provider = frmCanvas.TipoConexao  
205 -  
206 -If (frmCanvas.TipoConexao = 4) Then  
207 -  
208 -If (contador <> 10) Then  
209 -  
210 -mSERVIDOR = ReadINI("CONEXAO", "SERVIDOR", App.path & "\CONTROLES\GEOSAN.ini")  
211 -mPORTA = ReadINI("CONEXAO", "PORTA", App.path & "\CONTROLES\GEOSAN.ini")  
212 -mBANCO = ReadINI("CONEXAO", "BANCO", App.path & "\CONTROLES\GEOSAN.ini")  
213 -mUSUARIO = ReadINI("CONEXAO", "USUARIO", App.path & "\CONTROLES\GEOSAN.ini")  
214 -Senha = ReadINI("CONEXAO", "SENHA", App.path & "\CONTROLES\GEOSAN.ini")  
215 -username = ReadINI("CONEXAO", "USER", App.path & "\CONTROLES\GEOSAN.ini")  
216 -frmCanvas.FunDecripta (Senha)  
217 -decriptada = frmCanvas.Senha  
218 -  
219 -TeAcXConnection1.Open mUSUARIO, decriptada, mBANCO, mSERVIDOR, mPORTA  
220 -contador = 10  
221 -  
222 -Else  
223 -  
224 -TePrinter1.Provider = frmCanvas.TipoConexao  
225 -'TePrinter1.connection = TeAcXConnection1.objectConnection_  
226 -  
227 -End If  
228 -  
229 -Else  
230 -TePrinter1.Provider = frmCanvas.TipoConexao  
231 -TePrinter1.connection = Conn  
232 -  
233 -End If  
234 -  
235 -TePrinter1.execute  
236 -  
237 -End Sub  
238 -  
239 -Private Sub Form_Resize()  
240 -On Error GoTo Trata_Erro  
241 -  
242 -TePrinter1.Width = 9960  
243 -TePrinter1.Height = Me.Height - 1250 '- tbMain.Height  
244 -  
245 -Trata_Erro:  
246 -  
247 -If Err.Number = 0 Or Err.Number = 20 Then  
248 - Resume Next  
249 -Else  
250 - Exit Sub  
251 -End If  
252 -  
253 -End Sub  
254 -  
255 -Private Sub mn8_Click()  
256 - MudaFonte 8  
257 -End Sub  
258 -  
259 -Private Sub mn12_Click()  
260 -  
261 -  
262 - TePrinter1.setObjectPropertyValue ObjName, 6, 12 'CLng(tamanho)  
263 - TePrinter1.execute  
264 -  
265 -End Sub  
266 -  
267 -Private Sub mn16_Click()  
268 - MudaFonte 16  
269 -End Sub  
270 -  
271 -Private Sub mn32_Click()  
272 - MudaFonte 32  
273 -End Sub  
274 -  
275 -  
276 -  
277 -Private Sub mnAfastar_Click()  
278 - TePrinter1.setMapMode zoomOut  
279 -End Sub  
280 -  
281 -Private Sub mnAproximar_Click()  
282 - TePrinter1.setMapMode zoomIn  
283 -End Sub  
284 -  
285 -Private Sub mnArial_Click()  
286 - MudaTipoFonte "Arial"  
287 -End Sub  
288 -  
289 -Private Sub mnCourrier_Click()  
290 - MudaTipoFonte "Arial Black"  
291 -End Sub  
292 -  
293 -Private Sub mnLucConsole_Click()  
294 - MudaTipoFonte "Lucida Console"  
295 -End Sub  
296 -  
297 -Private Sub mnConfPagina_Click()  
298 - If TePrinter1.orientation = portrait Then  
299 - frmPageSetup.setOrientation True  
300 - Else  
301 - frmPageSetup.setOrientation False  
302 - End If  
303 -  
304 - frmPageSetup.setPageSize TePrinter1.PaperSize  
305 -  
306 - frmPageSetup.Show 1, Me  
307 - If frmPageSetup.getOK = True Then  
308 - If frmPageSetup.getOrientation = True Then  
309 - TePrinter1.orientation = portrait  
310 - Else  
311 - TePrinter1.orientation = landscape  
312 - End If  
313 - TePrinter1.PaperSize = frmPageSetup.getPageSize  
314 -  
315 - TePrinter1.execute  
316 - End If  
317 -End Sub  
318 -  
319 -  
320 -  
321 -  
322 -  
323 -  
324 -  
325 -Private Sub mnImagem_Click()  
326 - cmmOpen.ShowOpen  
327 - TePrinter1.addImage cmmOpen.FileName  
328 -End Sub  
329 -  
330 -Private Sub mnImprimir_Click()  
331 -  
332 - TePrinter1.printExecute ("Teste")  
333 -  
334 -End Sub  
335 -  
336 -Private Sub mnLinha_Click()  
337 -  
338 - TePrinter1.addLine  
339 -  
340 -End Sub  
341 -  
342 -  
343 -  
344 -Private Sub mnMover_Click()  
345 - TePrinter1.setMapMode pan  
346 -End Sub  
347 -  
348 -Private Sub mnBarraEscala_Click()  
349 - TePrinter1.addScale  
350 -End Sub  
351 -  
352 -  
353 -  
354 -  
355 -Private Sub mnMapa_Click()  
356 -  
357 - 'COLETA AS VARIÁVEIS GLOBAIS PARA O MÓDULO DE IMPRESSÃO PASSADAS NO END PLOT VIEW  
358 - 'CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_  
359 -  
360 - 'ADICIONA O MAPA QUE ESTAVA NA TELA DO GEOSAN  
361 - 'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_  
362 -  
363 -If (frmCanvas.TipoConexao = 4) Then  
364 -  
365 -'TePrinter1.provider = TeComPrinterLib.CONNECTION_TYPE.PostgreSQL;  
366 -TePrinter1.addDatabase  
367 -TePrinter1.execute  
368 -'TePrinter1.Open ("nexussql.gpl")  
369 -'TePrinter1.execute  
370 -  
371 -  
372 -  
373 -TePrinter1.setObjectPropertyValueByName "Database_1", "left_Property", "15.0"  
374 -TePrinter1.execute  
375 -TePrinter1.setObjectPropertyValueByName "Database_1", "top_Property", "20.0"  
376 -TePrinter1.execute  
377 -TePrinter1.setObjectPropertyValueByName "Database_1", "width_Property", "11.0"  
378 -TePrinter1.execute  
379 -TePrinter1.setObjectPropertyValueByName "Database_1", "height_Property", "11.0"  
380 -TePrinter1.execute  
381 -TePrinter1.setObjectPropertyValueByName "Database_1", "angle_Property", "0.0"  
382 -TePrinter1.execute  
383 -  
384 -TePrinter1.setObjectPropertyValueByName "Database_1", "username_Property", "postgres"  
385 -TePrinter1.execute  
386 -TePrinter1.setObjectPropertyValueByName "Database_1", "password_Property", "gustavo"  
387 -TePrinter1.execute  
388 -TePrinter1.setObjectPropertyValueByName "Database_1", "host_Property", "localhost"  
389 -TePrinter1.execute  
390 -TePrinter1.setObjectPropertyValueByName "Database_1", "databasename_Property", "teste"  
391 -TePrinter1.execute  
392 -TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"  
393 -TePrinter1.execute  
394 -TePrinter1.setObjectPropertyValueByName "Database_1", "databasetype_Property", "2.0"  
395 -TePrinter1.execute  
396 -  
397 -  
398 -  
399 -TePrinter1.setObjectPropertyValueByName "Map_3", "viewname_Property", "Administrador"  
400 -TePrinter1.execute  
401 -TePrinter1.setObjectPropertyValueByName "Map_3", "viewuser_Property", "Administrador"  
402 -TePrinter1.execute  
403 -TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"  
404 -TePrinter1.execute  
405 -  
406 -TePrinter1.setObjectPropertyValueByName "Map_3", "left_Property", "15.0"  
407 -TePrinter1.execute  
408 -TePrinter1.setObjectPropertyValueByName "Map_3", "top_Property", "44.0"  
409 -TePrinter1.execute  
410 -TePrinter1.setObjectPropertyValueByName "Map_3", "width_Property", "300.0"  
411 -TePrinter1.execute  
412 -TePrinter1.setObjectPropertyValueByName "Map_3", "height_Property", "200.0"  
413 -TePrinter1.execute  
414 -TePrinter1.setObjectPropertyValueByName "Map_3", "angle_Property", "0.0"  
415 -TePrinter1.execute  
416 -  
417 -TePrinter1.setObjectPropertyValueByName "Map_3", "mapscale_Property", "2200000"  
418 -TePrinter1.execute  
419 -  
420 -TePrinter1.setObjectPropertyValueByName "Map_3", "fixedscale_Property", "False"  
421 -TePrinter1.execute  
422 -  
423 -  
424 -  
425 -  
426 -'TePrinter1.setObjectPropertyValueByName "Map_3", "connection_Property", "Database_1"  
427 -'TePrinter1.execute  
428 -  
429 -  
430 -'TePrinter1.addDatabase  
431 -  
432 -'TePrinter1.execute  
433 -'TePrinter1.setObjectPropertyValueByName "Database_1", "databaseconnected_Property", "true"  
434 -  
435 -  
436 -  
437 -  
438 -End If  
439 -  
440 -'update te_layer set lower_x = 715603;  
441 -'update te_layer set lower_y = 7702100;  
442 -'update te_layer set upper_x = 722075;  
443 -'update te_layer set upper_y = 7711330;  
444 -TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_  
445 -'TePrinter1.addMap strViewAtiva_, strUser, CanvasXmin_, CanvasYmin_, CanvasXmax_, CanvasYmax_  
446 -  
447 -End Sub  
448 -  
449 -Private Sub mnRetangulo_Click()  
450 - TePrinter1.addRectangle  
451 -End Sub  
452 -  
453 -Private Sub mnElipse_Click()  
454 - TePrinter1.addEllipse  
455 -End Sub  
456 -  
457 -Private Sub mnTexto_Click()  
458 - Dim Texto As String  
459 - Texto = InputBox("Informe o texto:")  
460 -  
461 - If Trim(Texto) <> "" Then  
462 - TePrinter1.addText Texto  
463 - End If  
464 -  
465 -End Sub  
466 -  
467 -  
468 -Private Sub TePrinter1_endProcess(ByVal partial As Boolean)  
469 -  
470 - DoEvents  
471 - If (partial = False) Then  
472 - 'mnProperties_Click  
473 - id_objeto  
474 - End If  
475 -End Sub  
476 -  
477 -